ADVICE FOR SAFETY

Before installation ensure that the local
distribution
conditions
pressure) and the pre-setting of the appliance
are consistent and the voltage and the
frecquency shown in the rating label
corresponds with your supply voltage.
This appliance belongs to class "X" in
matters of protection against overheating of
surrounding surfaces.
The neighbouring furniture panels has to be
heat proof or protected by such material.
Connection to gas main
Check that the counter flow and the
diameter of piping are enough to supply all
the appliances of the installation (take
counsel with the gas distribution company);
Check that all connections are tight;
Install an accessible and visible barrage tap;
If you use a flexible pipe it has to be easily
inspected all along and must not pass
behind the appliance;
Change the flexible pipe little before its
expire date stamped on it.
Placement
Remove the plastic packaging and install the
cooker in a dry, ventilated room (fig. 20) not near
curtains, paper, alcohol, petrol, etc...)
The appliance has to be set on a heatproof soil.
This appliance belongs to class "X" in matters of
protection against overheating of surrounding
surfaces.
It is mandatory to keep 2cm distance to the
furniture walls.
Ventilation
Gas combustion is possible due to the oxygen in
3
the air (2 m
air/h x kW installed power – check
the rating panel of the cooker).
It is necessary to renew the air and that the
combustion products be discharged.
The air flow must come directly through openings
of external walls having a free passage of at least
2
200 cm
. These openings should be realized
preferably positioned near the floor, opposite the
combustion products discharge. It should not be
occluded both from inside and outside.
The use of a gas cooking appliance produces,
heat and humidity in the room in which it is
installed. Ensure good ventilation of the room
keeping natural ventilation openings clear or
installing a mechanic ventilating device.
16

INSTRUCTIONS FOR THE INSTALLER

(gas
nature
and

INSTALLATION

Electric connection
Check that:
the power of the installation is enough;
the supplying lines are in good conditions;
the diameter of the cables complies with the
installation rules;
the fix installation has a device with contacts
with omnipolar switch with a minimum
opening between contacts of minimum3
mm.
Installation and maintenance have to be made
by a qualified person in accordance with the
regulations in force.
We deny any responsibility in cases of
accidents or incidents caused lack of
grounding or missgrounding.
min 15 cm
FOUR
TABLE
CGL 404
2 cm
fig. 20
61 cm
2 cm