Technical Data
Dimensions
TYPE OF
CHARACTERISTICS
GAS
VALUE =
NATURAL
37.78 MJ/m
GAS
3
20 mbar
Ws -
50.7 MJ/ m
3
LPG GAS
VALUE =
28-30/37
49.92 MJ/Kg
m b a r

Important Safety Requirements

Provision for Ventilation
3
3
3
22
BURNER
POSITION
MAX
NOMINAL THERMAL
POWER kW
3.0
NOMINAL FLOW
RATE m
3
/h
0.286
NOZZLE REFERENCE
119
1/100 mm
NOMINAL THERMAL
POWER kW
2.8
NOMINAL FLOW
RATE g/h
202
NOZZLE REFERENCE
1/100 mm
3
3
Hob
Oven
RAPID
SEMI-RAPID
(large)
(medium)
MIN
MAX
0.65
2.0
0.057
0.190
Adjust.
96
0.65
2.0
43.5
144
86
40
71
Location
2
2
AUXILIARY
(small)
MIN
MAX
MIN
0.45
1.0
0.33
0.038
0.095
0.028
Adjust.
70
Adjust.
0.45
1.0
0.33
29
72
21,5
32
50
28
3
3