Instructions for the Installer

Technical Data

APPLIANCE CATEGORY
APPLIANCE GAS SUPPLY
Dimensions
Hob
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE
NOZZLE REFERENCE
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE
NOZZLE REFERENCE

Important Safety Requirements

BURNER
ULTRA-RAPID
(large)
POSITION
MAX
3.5
m
/h
0.333
0.114
3
136
Adjust.
1/100 mm
3.5
g/h
252
93
1/100 mm
Oven
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
1.2
2.0
0.45
1.0
0.190
0.043
0.095
96
Adjust.
70
1.2
2.0
0.45
1.0
86.5
144
32
72
56
71
32
50

Provision for Ventilation

2
3
(small)
MIN
0.33
0.031
Adjust.
0.33
24
28
3
3
3
3
3
2
3
19

Advertisement

Table of Contents
loading

Table of Contents