Power Supply; Power Supply Failure: Single Power Supply Module - Supero SUPERSERVER 6026TT-BTF User Manual

2u twin2 (four serverboards/nodes in a 2u chassis) rackmount server
Table of Contents

Advertisement

6-7

Power Supply

The SuperServer 6026TT-BTF/6026TT-BIBXF/6026TT-BIBQF has a single 1400
watt power supply (you may add an additional power supply module for redundancy).
The power supply module has an auto-switching capability, which enables it to
automatically sense and operate at a 100V - 240V input voltage.

Power Supply Failure: Single Power Supply Module

If the power supply module fails, the system will shut down and you will need to
replace the module. Replacements can be ordered directly from Supermicro (see
contact information in the Preface).
As there is only one power supply module in the system, power must be com-
pletely removed from the server before removing and replacing the power supply
for whatever reason.
Removing/Replacing the Power Supply (Figure 6-7)
1.
First unplug the AC power cord from the system.
2.
Push the release tab on the back of the power supply.
3.
Pull the power supply out using the handle provided.
4.
Replace the failed power module with the same model (see Appendix C for
part number).
5.
Push the new power supply module into the power bay until you hear a click.
6.
Reconnect the AC power cord and depress the power button on the control
panel to restart the system.
Chapter 6: Advanced Chassis Setup