Procedure 7-12 To add 9500 MPR port protection

1
Choose Equipment from the navigation tree view selector. The navigation tree
displays the Equipment view.
2
Expand the 9500 MPR icon, right-click on the 9500 MPR object you need to
configure as the main port of the protection pair, and choose Properties from the
contextual menu. The Network Element (Edit) form opens with the General tab
displayed.
3
On the Network Element (Edit) form navigation tree, expand the Shelf icon.
4
Expand the Card Slot icon and click on the port object that you need to configure.
The Port (Edit) form opens with the General tab displayed.
5
Click on the Protection tab.
6
Configure the Protection Type parameter on the main/spare MPT port.
7
For radio ports, configure the parameters:
8
Click on the OK button. A dialog box appears.
Alcatel-Lucent 5620 Service Aware Manager, Release 11.0 R5
3HE 08459 AAAA TQZZA Edition 01
MPR User Guide
Note 1 — The Protection tab only appears for MPT-type ports of EAS
modules if the corresponding spare port is configured as MPT.
Note 2 — All cross-connections, flow-IDs, and synchronization sources
must be removed from the port under the spare card slot before
protection can be enabled.
Note 3 — To configure protection type 1+1 FD on MPT/Radio, the Mode
cannot be Adaptive Modulation.
Note 4 — In Release 3.0.0, for the 2+2 EAS MPT ports, the protect port
can be chosen as the consecutive port of the same card or the same port
of the corresponding even slot.
Note 5 — MPT-HC/MC pair protection can be configured on the
core-enhanced card. When an MPT pair (MPT-HC or MPT-HCv2 with RPS
module, or MPT-MC) is used for a protected configuration, both MPTs
must use the same type of GigE port (optical or electrical), to use the
same IDU-ODU synchronization method.
Restoration Criteria in the Receiver Protection Scheme Parameters panel
Commands Receiver Protection Scheme Parameters panel
Restoration Criteria in the Transmitter Protection Scheme Parameters panel.
Commands in the Transmitter Protection Scheme Parameters panel.
Note — For Protection Type, 1+1 FD, Transmitter Protection Scheme
parameters are not applicable.
7 — 9500 MPR/9500 MPRe port object configuration
September 2013
7-15