MSS-4 and MSS-8 shelves

Slots 1 and 2 are reserved for core-enhanced cards. Each shelf requires a
core-enhanced card in slot 1 and can have an optional spare card installed in slot 2 to
protect the main card.
The MSS-4 shelf supports cards in slots 3 and 4. A card in slot 3 can be protected by
an identical card in slot 4.
The MSS-8 shelf supports cards in slots 3 to 8. Protected cards must be installed in
slots 3, 5, or 7 and are protected by optional identical cards in slots 4, 6, and 8,
respectively.

9500 MPR/9500 MPRe card support

See
"Working with card and card slot objects on 9500 MPR/9500 MPRe devices"
chapter
devices.

Fan tray

The 9500 MPR supports two fan tray types: basic and advanced. For the advanced
fan tray, you can configure four ports for housekeeping alarms. See Procedure
for more information about configuring a 9500 MPR fan tray.

ODU

The ODU is a microprocessor-controlled transceiver that interfaces the MSS with the
microwave antenna. Each radio modem card connects to one ODU. A 1+0 radio
modem protection scheme requires one radio modem card and one ODU for each
radio direction. Two radio modem cards and two associated ODUs must be
provisioned in each radio direction for the 1+1 protection scheme.

XPIC

XPIC is an ODU that draws power and data from a 2+2 × Ethernet (EAS) card when
the port is configured as MPT-HC. See Procedure
type over Ethernet on a 2+2 × Ethernet (EAS) card. See the 9500 MPR user
documentation for more information about how to use the NEtO software to
configure XPIC.

9500 MPR LAG objects

The 5620 SAM supports the configuration and discovery of the L1 LAG associations
from the 5620 SAM or NEtO external element manager for equipment functions on
the 9500 MPR (ANSI and ETSI), Release 3.4 or later. See chapter 5.

9500 MPR services and service tunnel support

The 5620 SAM supports the configuration of VLANs, VLLs, and composite services
on 9500 MPR devices. See chapter
Alcatel-Lucent 5620 Service Aware Manager, Release 11.0 R5
3HE 08459 AAAA TQZZA Edition 01
MPR User Guide
6
for the supported cards and auxiliary equipment on 9500 MPR/9500 MPRe
2 — 9500 MPR/9500 MPRe overview
7-11
to configure power source
9
for an overview of supported services.