Clearing The Password; Recovering Bios Defaults - MAXDATA PLATINUM 2200 IR User Manual

Hide thumbs Also See for PLATINUM 2200 IR:
Table of Contents

Advertisement

Clearing the Password

If the user or administrator password(s) is lost or forgotten, moving the password clear jumper into
the "clear" position clears both passwords. The password clear jumper must be restored to its original
position before a new password(s) can be set. The password clear jumper is shown in figure 5.
1. Power down the server. Do not unplug the power cord.
. Open the server chassis.
. Move the jumper from the default operating position (covering pins 1 and ) to the Password
Clear position (covering pins  and ).
4. Close the server chassis.
5. Power up the server and wait 10 seconds.
6. Power down the server.
7. Open the server chassis and move the jumper back to the default position (covering pins 1
and ).
8. Close the server chassis.
9. Power up the server.

Recovering BIOS Defaults

If you are not able to access the BIOS setup screens, the BIOS Defaults jumper will need to be used
to reset the system configuration. The BIOS Defaults jumper is shown in figure 5.
1. Power down the system and unplug the power cord.
. Open the server chassis.
. Move the jumper from the default operating position (covering pins 1 and ) to the reset/clear
position (covering pins  and ).
4. Wait 5 seconds.
5. Move the jumper back to the default position (covering pins 1 and ).
6. Close the server chassis.
7. Power up the server.
MAXDATA Server PLATINUM 00 IR M7
9