Step 4. Code I.D.
In
Appendix
format. Locate the Hex value for that symbology and scan the 2 digit
hex value from the
manual.
Step 5. Length
Specify what length (up to 9999 characters) of data will be acceptable
for this symbology. Scan the four digit data length from the
Programming Chart
characters is entered as 0050. 9999 is a universal number, indicating
all lengths.)
Step 6. Editor Commands
Refer to
that represent the command you want to enter. 94 alphanumeric char-
acters may be entered for each symbology data format.
Step 7. Scan Save from the
manual to save your entries.

Other Programming Selections

• Clear One Data Format
This deletes one data format for one symbology. If you are clearing the
primary format, scan 0 from the
this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending
on the alternate format you are clearing. Scan the Terminal Type and Code
I.D. (see
Supported Terminals
the specific data format that you want to delete. All other formats remain
unaffected.
• Save from the
This exits, saving any Data Format changes.
• Discard from the
This exits without saving any Data Format changes.

Data Format Editor Commands

Send Commands
F1 Send all characters followed by "xx" key or function code, starting from cur-
rent cursor position. Syntax = F1xx (xx stands for the hex value for an
ASCII code, see
F2 Send "nn" characters followed by "xx" key or function code, starting from
current cursor position. Syntax = F2nnxx (nn stands for the numeric value
(00-99) for the number of characters and xx stands for the hex value for an
ASCII code. See
F3 Send up to but not including "ss" character (Search and Send) starting from
current cursor position, leaving cursor pointing to "ss" character followed by
"xx" key or function code. Syntax = F3ssxx (ss and xx both stand for the
hex values for ASCII codes, see
1252), page A-4.)
5 - 2
A, find the symbology to which you want to apply the data
Programming Chart
inside the back cover of this manual. (Note: 50
Data Format Editor Commands
Programming Chart
Programming Chart
Programming Chart
ASCII Conversion Chart (Code Page
ASCII Conversion Chart (Code Page
inside the back cover of this
(page 5-2). Scan the symbols
inside the back cover of this
Programming Chart
on page 2-2), and the barcode data length for
inside the back cover of this manual
inside the back cover of this manual
ASCII Conversion Chart (Code Page
inside the back cover of
1252), page A-4.)
1252), page A-4.)