GAS CONVERSIONS
IMPORTANT:
Gas conversions from Natural gas to LP gas must
be done by a qualified installer.
Explosion
Hazard
Use a new CSA International
approved
gas supply line.
Install a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples
of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
1.
2.
Turn the manual shutoff valve to the closed position.
Unplug cooktop or disconnect
power.
...................
B
J
................
......................
C
A. To eooktop
B. Shutoff valve (closed position)
C. Gas supply line
To Convert
Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "NAT" or "LP" position. Turn over the spring
retainer so the "LP" is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
E
D
Z__
C
A. Access cap
D. LP position
B. Gasket
E. NAT position
C. Gas pressure regulator
3.
Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
LP Gas:
Minimum pressure 11" (27.9 cm) WCP
Supply pressure 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial rating plate.
Line pressure testing
above 1/2psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be
disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2psi (3.5 kPa).
Line pressure testing
at 1/2psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2psi (3.5 kPa).
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove burner cap.
3. Remove the burner head.
NOTE: A 7/8"socket must be used to remove the burner head
of the large dual burners.
4. Using a T15 Torx _ screwdriver, remove the burner base.
Large Dual Burner
A. Burner cap
B. Burner head
C
C. Gas opening
)_,""""_ D
D. Burner base
14