Maytag MEW5524AS0 Installation Instructions Manual page 4

24" (60 cm) electric built-in oven
Hide thumbs Also See for MEW5524AS0:
Table of Contents

Advertisement

Available languages

Available languages

A. _/' (5 mm)
Installed in Built-In Cabinet
C
B
A. 1_"
(3.0 cm) maximum
B. 19_" (50.0 cm) minimum
C. 21 _" (55.0 cm) minimum
D. 22" (56.0 cm) minimum
E. 23+ _"
(58.3+0.2 mm)
Ifcodes permitand a separateground wireisused, it is
recommended
that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance
with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. O-M91-1atest edition, and
all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Electrical
Connection
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial
number rating
plate. The model/serial
number rating plate is located on the
right vertical part of the oven frame. See the following
illustration.
A. Model/serial
number plate
Models rated 3.6 kW and below at 120/240 volts require a
separate 15-amp circuit. Models rated 3.6 to 4.8 kW at
120/240 volts require a separate 20-amp circuit.
A circuit breaker is recommended.
Connect directly to the circuit breaker box (or fused
disconnect) through flexible, armored or nonmetallic
sheathed, copper cable (with grounding wire). See "Make
Electrical Connection"
section.
CSA approved flexible conduit from the oven should be
connected directly to the junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
A CSA approved conduit connector must be provided.
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the ends of the
CSA approved flexible conduit leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors
and/or tools
designed for joining copper to aluminum.
Follow the electrical connector manufacturer's
recommended
procedure. Aluminum/copper
connection must conform with
local codes and industry accepted wiring practices.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wos52em4as0

Table of Contents