Vogelzang International PERFORMER TR009 Owner's Manual

Vogelzang International PERFORMER TR009 Owner's Manual

The performer high-efficiency woodstove epa certified (3.89 grams/hr.)
Hide thumbs Also See for PERFORMER TR009:

Advertisement

THE PERFORMER
HigH-EFFiciEncy WOOdsTOvE
Model TR009 Owners Manual
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLINg OR OPERATINg
ThIS STOvE. FAILURE TO FOLLOw
INSTRUCTIONS MAY RESULT IN PROP-
ERTY DAMAgE, BODILY INjURY, OR
EvEN DEATh.
VGZ-029 / 20110519.0
EPA Certified (3.89 grams/hr.)
(save this manual for future reference)
U.S. Test Standard:
DO nOT USE ThIS STOvE IN A
MOBILE hOME, MANUFACTURED hOME,
TENT OR TRAILER – No ExcEptioNs!
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
TR009 PERFORMER™ / Page 1
This stove meets
UL 1482-2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PERFORMER TR009 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vogelzang International PERFORMER TR009

  • Page 1 ERTY DAMAgE, BODILY INjURY, OR MOBILE hOME, MANUFACTURED hOME, EvEN DEATh. TENT OR TRAILER – No ExcEptioNs! Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 1...
  • Page 2: Safety Precautions

    Your insurance company should be able to rec- ommend a qualified inspector. continued on next page Page 2 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 3 National Fire Protection Association (NFPA) publication, “Using Coal and Wood Stoves Safely” NFPA No. HS-10- 1978. The address of the NFPA is Batterymarch Park, Quincy, MA 02269. VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 3...
  • Page 4: Table Of Contents

    PARTS – gLASS DOOR (glass Replacement) ..........19 PARTS – FIRE BRICk ..................19 OPTIONAL F-6 BLOwER wIRINg DIAgRAM ..........20 FLOOR PROTECTOR CALCULATIONS ............21 ChIMNEY CONNECTION SYSTEMS & CLEARANCES ........22 Page 4 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 5: Tools And Materials Required For Installation

    AssEmblY iNstRUctioNs NoticE: Vogelzang international corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND MATERIALS REqUIRED of the stove to direct combustion gasses over the...
  • Page 6 Secure with four sheet metal screws. 14. After assembly, check to make sure fire brick are properly positioned and ash clean out cover is in place. Figure 7 – Attach pedestal to stove body Page 6 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 7: Locating The Stove

    AND EXTENDING 2” BEYOUND EACH SIDE 36" 11"min 11"min. 47" Minimum 20" Clearances SIDEWALL according to UL 1482-2006 FLOOR 16"min. 20" PROTECTOR 24" 6"min. min. Fig. 10 – top ViEw minimum clearance Dimensions from combustible surfaces VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 7...
  • Page 8: Firebrick Assembly

    Six (6) A-size Four (4) A-size One (1) C-size One (1) B-size One (1) D-size Two (2) E-size Fig.13c– step 3, back Firebrick Arrangement Figure 13a – step 1, bottom Firebrick Arrangement Page 8 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 9: Connector Pipe Installation

    With lower exhaust temperatures, it is important that the chimney is correctly sized to the stove. If the chimney diameter is too large, it will be dif- VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 9...
  • Page 10: Chimney Connections/Draft

    5. C o n t a c t y o u r l o c a l b u i l d i n g a u t h o r i t y Figure 16 - chimney construction for approved methods of installation and any through Attic space necessary permits and/or inspections. Page 10 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 11 Figure 18 - chimney connection to Firebox tified Chimney Sweep, or a knowledgeable inspector. through masonry wall continued on next page VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 11...
  • Page 12: Fireplace Installation

    Fire Protection Association (NFPA) and request a copy of the latest editions of NFPA Standard 211 and NFPA Standard 908. Their address is: Battery March Park, Quincy, MA 02269. Figure 19 - Fireplace conversion Page 12 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 13: Operating Instructions

    These secondary flames should continue to burn after the primary air inlet is reset from wide open to the desired operating setting. If the flames do not continued on next page VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 13...
  • Page 14: Starting A Fire, Adding Fuel

    6. Adjust the air inlet control as described above. 6. This unit is designed to function most effectively when air is allowed to circulate to all areas of the continued on next page Page 14 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 15: Service Hints

    VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 15...
  • Page 16: Chimney Draft

    High pressure weather (clear and cold) possible until the stove is used again. usually produces a better chimney draft than low Page 16 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 17: Glass Care & Replacement, Glass Gasket Replacement

    Inspect glass and door gaskets periodically to ensure proper seal; if gaskets become frayed or worn, replace immediately. VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 17...
  • Page 18: Parts - Performer

    - tR009 pERFoRmER™ stoVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts.
  • Page 19: Parts - Glass Door (Glass Replacement)

    - tR009 pERFoRmER™ stoVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts.
  • Page 20: Optional F-6 Blower Wiring Diagram

    DiAgRAm - moDEl F-6 blowER optioN Page 20 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 21: Floor Protector Calculations

    Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem Step 4: Compare Rsystem to Rspecs Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative. VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 21...
  • Page 22: Chimney Connection Systems & Clearances

    24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Page 22 / TR009 PERFORMER™ VGZ-029 / 20110519.0...
  • Page 23 VGZ-029 / 20110519.0 TR009 PERFORMER™ / Page 23...
  • Page 24 “FOR gOD SO LOvED ThE wORLD ThAT hE gAvE hIS ONLY BEgOTTEN SON, ThAT whOEvER BELIEvES IN HIM SHaLL NoT PERISH BuT HavE ETERNaL LIFE” jOhN 3:16 MADE IN ChINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 24 / TR009 PERFORMER™ VGZ-029 / 20110519.0...

Table of Contents

Save PDF