Vogelzang International Performer TR009 Owner's Manual

Vogelzang International Performer TR009 Owner's Manual

The performer high-efficiency woodstove epa certified (3.89 grams/hr.)
Hide thumbs Also See for Performer TR009:

Advertisement

Quick Links

THE PERFORMER
HIGH-EFFICIENCY WOODSTOVE
Model TR009 Owners Manual
Le manuel de langue français est disponible à www.vogelzang.com
French language manual is available at www.vogelzang.com
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS
ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
VGZ-029 / 20120113.0
EPA Certified (3.89 grams/hr.)
(Save These Instructions)
This stove meets test standards:
US: UL 1482-2010 & CDN: ULC-S627-00
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
EQUIPMENT INSTALLER!
DO NOT INSTALL IN A MOBILE HOME.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
TR009 PERFORMER™ / Page 1
Report No. 180-S-06b-2

Advertisement

Table of Contents
loading

Summary of Contents for Vogelzang International Performer TR009

  • Page 1 RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 1...
  • Page 2: Safety Precautions

    TO AN ALUMINUM TYPE B GAS VENT. This is construction of the fire box. This should disappear not safe. Use approved masonry or an Underwrit- ers Laboratories Listed UL 103 HT / ULC-S629 continued on next page Page 2 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 3 29. DO NOT CONNECT TO OR USE IN CONJUNC- 1978. The address of the NFPA is Batterymarch TION WITH ANY AIR DISTRIBUTION DUCT Park, Quincy, MA 02269. WORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS. VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 3...
  • Page 4: Table Of Contents

    PARTS – FIRE BRICK ..................22 FLOOR PROTECTOR CALCULATIONS ............23 NOTE: A PROFESSIONAL, LICENSED HEAT- ING AND COOLING CONTRACTOR MUST BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THIS SOLID FUEL BURNING APPLIANCE. Page 4 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 5: Tools And Materials Required For Installation

    ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND MATERIALS REQUIRED of the stove to direct combustion gasses over the...
  • Page 6 Secure with four sheet metal screws. 14. After assembly, check to make sure fire brick are properly positioned and ash clean out cover is in place. Figure 7 – Attach Pedestal to Stove Body Page 6 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 7: Locating The Stove

    ULC S627 FLOOR FLOOR 16"min. 18"/46cm min. PROTECTOR PROTECTOR 20" 24"/61cm 24" 6"min. 24"/61cm 8"/21cm min. min. min. Fig. 10 – TOP VIEW Minimum Clearance Dimensions from Combustible Surfaces VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 7...
  • Page 8 Figure 11a – Front View Figure 11b – Side View Minimum Clearance Dimensions from Combustible Surfaces Figure 11c – Front View Figure 11d – Side View Minimum Clearance Dimensions from Combustible Surfaces Page 8 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 9: Firebrick Assembly

    With lower exhaust temperatures, it is important that the chimney is correctly sized to the VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 9...
  • Page 10: Connector Pipe Installation

    flue to run back into the firebox. 2. Horizontal pipe runs must slope upwards towards the chimney at least 1/4”(6.4mm) per foot of horizontal run. Figure 14 – Stovepipe/Flue Connections Page 10 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 11: Chimney Connections/Draft

    5. C o n t a c t y o u r l o c a l b u i l d i n g a u t h o r i t y for approved methods of installation and any necessary permits and/or inspections. Figure 16 - Chimney Construction through Attic Space VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 11...
  • Page 12 Chimney Sweep, or a knowledgeable inspector. Figure 18 - Chimney Connection to Firebox Consult your insurance company if you cannot find a through Masonry Wall qualified expert. continued on next page Page 12 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 13 NFPA Standard 211 and NFPA be done by a qualified installer. Standard 908. Their address is: Battery March Park, Quincy, MA 02269. Figure 19 - Fireplace Conversion VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 13...
  • Page 14: Chimney Connection Systems & Clearances

    24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Page 14 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 15: Operating Instructions

    ESPECIALLY GASOLINE, OUT OF THE height, weather, log size, wood species and moisture VICINITY OF THE STOVE — WHETHER IN USE content. Some experimentation will initially be required OR IN STORAGE. continued on next page VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 15...
  • Page 16: Starting A Fire

    This procedure will 3. Cover the paper with a generous amount of kin- dling in a teepee fashion and a few small pieces of continued on next page wood. Page 16 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 17: Service Hints

    The use of green or wet wood will cause a rapid build up of creosote. Wood that hisses, sizzles and blackens without igniting in five minutes must be considered too wet to burn. continued on next page VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 17...
  • Page 18: Chimney Draft

    Without the correct amount of draft, the stove will not the first fifteen to thirty minutes after starting the fire. operate properly. Be careful not to over fire the stove. If any part of Page 18 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 19: Glass Care & Replacement

    4. Do not clean the glass with materials that may scratch (or otherwise damage) the glass. Scratches on the glass can develop into cracks or breaks dur- ing operation. continued on next page VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 19...
  • Page 20: Glass Gasket Replacement

    AND WHENEVER SERVICING BLOWER ASSEMBLY. NOTICE: ANY REPLACE- MENT WIRING MUST HAVE E Q U I VA L E N T I N S U L A - TION AND TEMPERATURE RATING (105°C). Page 20 / TR009 PERFORMER™ VGZ-029 / 20120113.0...
  • Page 21: Parts - Performer

    ORDERING PARTS - TR009 PERFORMER™ STOVE When ordering missing or replacement parts, always give the of the stove, , and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. 3, 38, 39...
  • Page 22: Parts - Glass Door (Glass Replacement)

    PARTS - TR009 PERFORMER™ STOVE When ordering missing or replacement parts, always give the of the stove, , and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. Ref. Part No.
  • Page 23: Floor Protector Calculations

    Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem Step 4: Compare Rsystem to Rspecs Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative. VGZ-029 / 20120113.0 TR009 PERFORMER™ / Page 23...
  • Page 24 “FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT WHOEVER JOHN 3:16 MADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 24 / TR009 PERFORMER™ VGZ-029 / 20120113.0...

Table of Contents