HIGH-EFFICIENCY WOODSTOVE
Model TR008 Owners Manual
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS
ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
TR008-96 | 20120425.0
THE DURANGO
EPA Certified (3.6 grams/hr)
(save this manual for future reference)
www.vogelzang.com
This stove meets test standards:
US: UL 1482-1996
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
EQUIPMENT INSTALLER!
DO NOT INSTALL IN A MOBILE HOME.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
Report No. 180-S-04-2
DURANGO™ | Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the THE DURANGO TR008 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vogelzang International THE DURANGO TR008

  • Page 1 SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...
  • Page 2: Safety Precautions

    17. DO NOT ELEVATE THE FIRE. Build fire directly on FLUE SERVING ANOTHER APPLIANCE. the bottom of the firebox. This stove has not been tested with the use of grates, andirons or other means Page 2 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 3 SAFETY INSTRUCTIONS continued… of elevating the fire and must not be used. TION WITH ANY AIR DISTRIBUTION DUCT WORK UNLESS SPECIFICALLY APPROVED FOR SUCH 18. The special paints used on your stove may give INSTALLATIONS. off some smoke and an odor while they are cur- ing during the first 12 to 15 fires.
  • Page 4: Table Of Contents

    CHIMNEY & STOVE MAINTENANCE LOG ............23 NOTE: A LICENSED PROFESSIONAL HEAT- ING AND COOLING CONTRACTOR SHOULD BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THIS SOLID FUEL BURNING APPLIANCE. Page 4 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 5: Tools And Materials Required For Installation

    ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND MATERIALS REQUIRED FOR INSTALLATION TOOLS chimney. or your stove will not operate properly.
  • Page 6: Locating The Stove

    5 – 7. fire protection ordinances. 2. The stove must have its own flue. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING OTHER APPLIANCES. continued on next page Vogelzang International Corp. Page 6 | DURANGO™ TR008-96 | 20120425.0...
  • Page 7: Floor Protector, Minimum Clearances

    LOCATING STOVE continued… NOTE: ANY WALL CONTAINING COMBUSTI- CAUTION: FAILURE TO FOLLOW THESE BLE MATERIAL SUCH AS WOODEN STUDS OR M I N I M U M C L E A R A N C E R E Q U I R E - DRYWALL AND FACED WITH BRICK OR STONE M E N T S M AY R E S U LT I N A N U N S A F E MUST BE CONSIDERED A COMBUSTIBLE...
  • Page 8: Firebrick Assembly

    NECTOR PIPE AS A CHIMNEY - A HOUSE FIRE COULD RESULT. NOTE: CONNECTOR PIPE IS NOT INCLUDED. TO PURCHASE, VISIT YOUR LOCAL HARD- WARE, HOME OR BUILDING CENTER. SEE SPECIFICATIONS. Fig.9 – Stovepipe/Flue Connections Page 8 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 9: Chimney Sizing

    CHIMNEY SIZING Today’s solid fuel heating appliances are much stove. If the chimney diameter is too large, it will be dif- more efficient than those made in the past. Your heat- ficult to raise the chimney flue temperature to provide for ing appliance has been designed to provide the most adequate draft.
  • Page 10 If a chimney does Fig. 12 - Chimney Construction Through Roof not have a liner, or it is damaged, have it relined by a Page 10 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 11 CHIMNEY CONNECTIONS continued … professional. Do Not use a chimney that is unlined or damaged!) If you have any question regarding the condition of the chimney, consult a qualified licensed contractor, qualified engineer, competent mason, cer- tified Chimney Sweep, or a knowledgeable inspector. Consult your insurance company if you cannot find a qualified expert.
  • Page 12: Chimney Connection Systems & Clearances

    24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Page 12 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 13: Operating Instructions

    OPERATING INSTRUCTIONS THIS STOVE IS DESIGNED TO CAUTION: HOUSE FIRE HAZARDS BURN WOOD FUEL ONLY! THIS STOVE IS DESIGNED TO BURN TECTOR, UNDERNEATH STOVEPIPE OR ANY- WOOD FUEL ONLY! WHERE WITHIN MINIMUM CLEARANCES FROM Hardwood, 18”/46cm to 26”/66cm must be air dried COMBUSTIBLE SURFACES SPECIFIED FOR (seasoned) for a minimum of 6 months.
  • Page 14: Starting A Fire, Adding Fuel

    5. Add large pieces of wood as the fire progresses Do not build fires against glass and make sure the being careful not to overload. (Do not fill firebox continued on next page Page 14 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 15: Service Hints

    OPERATING continued... SERVICE HINTS coal bed does not obstruct the air inlet. Do not load CREOSOTE – FORMATION AND NEED FOR fuel to a height or in such a manner that it creates REMOVAL a hazard when opening the door. 4.
  • Page 16: Chimney Draft

    If there is excessive draft, an unsafe condition will the stove or chimney starts to glow, you are over arise with too much air being drawn into the stove and continued on next page Page 16 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 17: Glass Care & Replacement, Glass Gasket Replacement

    SERVICE HINTS continued... firing the stove. Masonry chimneys will take longer 4. Do not clean the glass with materials that may to warm than manufactured chimneys on account of scratch (or otherwise damage) the glass. Scratches their greater structural mass. Chimneys that have a on the glass can develop into cracks or breaks dur- flue diameter larger than the stove outlet take more ing operation.
  • Page 18: Blower Wiring Diagram

    AND WHENEVER SERVICING BLOWER ASSEMBLY. NOTICE: ANY REPLACE- MENT WIRING MUST HAVE E Q U I VA L E N T I N S U L A - TION AND TEMPERATURE RATING (105°C). Page 18 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 19: Parts - Durango

    PARTS - TR008 DURANGO HIGH-EFFICIENCY STOVE When ordering missing or replacement parts, always give the of the stove, , and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. TR008-96 | 20120425.0 www.vogelzang.com DURANGO™...
  • Page 20: Parts - Fire Brick

    Ceramic Gasket ........1 08-13F Fire Brick “F” ..........2 F-6S Phillips Head Machine Screw (sm) ..... 08-13G Fire Brick “G” ..........1 08-13H Fire Brick “H” ..........1 08-13K Fire Brick “K” ..........1 FIREBRICK LAYOUT Page 20 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 21: Parts - Glass Door (Glass Replacement)

    PARTS - TR008 DURANGO HIGH-EFFICIENCY STOVE When ordering missing or replacement parts, always give the of the stove, , and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. Part No. Description Qty.
  • Page 22: Floor Protector Calculations

    Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem Step 4: Compare Rsystem to Rspecs Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative. Page 22 | DURANGO™ Vogelzang International Corp. TR008-96 | 20120425.0...
  • Page 23: Chimney & Stove Maintenance Log

    CHIMNEY & STOVE MAINTENANCE LOG DATE OF SERVICE PERFORMED BY DESCRIPTION TR008-96 | 20120425.0 www.vogelzang.com DURANGO™ | Page 23...
  • Page 24 TRAILER OR TENT — NO EXCEPTIONS! COMPANY TESTIMONY: “FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT WHOEVER JOHN 3:16 MADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 24 | DURANGO™...

Table of Contents