Vogelzang International Performer TR009 Owner's Manual
Vogelzang International Performer TR009 Owner's Manual

Vogelzang International Performer TR009 Owner's Manual

High-efficiency woodstove epa certified (3.89 grams/hr)
Hide thumbs Also See for Performer TR009:

Advertisement

Quick Links

HigH-EFFiciEncy WOOdsTOvE
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLINg OR OPERATINg
ThIS STOvE. FAILURE TO FOLLOw
INSTRUCTIONS MAY RESULT IN PROP-
ERTY DAMAgE, BODILY INjURY, OR
EvEN DEATh.
VGZ-029 / 060209
NorthlineExpress.com
THE PERFORMER
EPA Certified (3.89 grams/hr)
Model TR009 Owners Manual
(save this manual for future reference)
http://www.northlineexpress.com
This stove meets
U.S. Test Standard:
UL 1482-2006
DO nOT USE ThIS STOvE IN A
MOBILE hOME, MANUFACTURED hOME,
TENT OR TRAILER – No ExcEptioNs!
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
TR009 PERFORMER™ / Page 1
Toll-Free 1-866-667-8454

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Performer TR009 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vogelzang International Performer TR009

  • Page 1 ERTY DAMAgE, BODILY INjURY, OR MOBILE hOME, MANUFACTURED hOME, EvEN DEATh. TENT OR TRAILER – No ExcEptioNs! Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 VGZ-029 / 060209 TR009 PERFORMER™ / Page 1 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 2: Safety Instructions

    Have the chimney inspected or abuse. When installing your stove, use care by the fire department or a qualified inspector. continued on next page Page 2 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 3 National Fire Protection Association (NFPA) publication, “Using Coal and Wood Stoves Safely” NFPA No. HS-10- 1978. The address of the NFPA is Batterymarch Park, Quincy, MA 02269. VGZ-029 / 060209 TR009 PERFORMER™ / Page 3 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 4: Table Of Contents

    PARTS – PERFORMER™ ................. 18 PARTS – gLASS DOOR (glass Replacement) ..........19 OPTIONAL F-6 BLOwER wIRINg DIAgRAM ..........19 FLOOR PROTECTOR CALCULATIONS ............19 ChIMNEY CONNECTION SYSTEMS & CLEARANCES ........20 Page 4 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 5: Tools And Materials Required For Installation

    AssEmblY iNstRUctioNs NoticE: Vogelzang international corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND MATERIALS REqUIRED 2. Remove parts and hardware pack located inside FOR INSTALLATION firebox.
  • Page 6 14. After assembly, check to make sure fire brick are properly positioned and ash clean out cover is in place. Figure 7 – Attach pedestal to stove body Page 6 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 7: Locating The Stove

    AND EXTENDING 2” BEYOUND EACH SIDE 36" 11"min 11"min. 47" 20" SIDEWALL FLOOR 16"min. PROTECTOR 20" 24" 6"min. min. Fig. 10 – top ViEw minimum clearance Dimensions from combustible surfaces VGZ-029 / 060209 TR009 PERFORMER™ / Page 7 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 8: Minimum Clearances

    Four (4) A-Size One (1) C-Size One (1) B-Size One (1) D-Size Two (2) E-Size Fig.13c– step 3, back Firebrick Arrangement Figure 13a – step 1, bottom Firebrick Arrangement Page 8 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 9: Connector Pipe Installation

    More efficient heat transfer into the living area safety hazards. means less heat lost up the chimney and cooler chim- VGZ-029 / 060209 TR009 PERFORMER™ / Page 9 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 10: Chimney Connections/Draft

    5. C o n t a c t y o u r l o c a l b u i l d i n g a u t h o r i t y for approved methods of installation and any necessary permits and/or inspections. Figure 16 - chimney construction through Attic space Page 10 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 11 Chimney Sweep, or a knowledgeable inspector. continued on next page VGZ-029 / 060209 TR009 PERFORMER™ / Page 11 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 12 Positioning the center of the stove pipe entry into the chimney 24” below the ceiling should insure proper clearance for a 6” stove- Figure 19 - Fireplace conversion pipe. Page 12 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 13: Operating Instructions

    These secondary flames should continue to burn after the primary air inlet is reset from wide open to the desired operating setting. If the flames do not continued on next page VGZ-029 / 060209 TR009 PERFORMER™ / Page 13 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 14 Instructions, item #14 on page 2.) 6. This unit is designed to function most effectively when air is allowed to circulate to all areas of the continued on next page Page 14 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com...
  • Page 15: Service Hints

    Operate the stove at a fire level high SPECTED BY A qUALIFIED EXPERT BEFORE enough to keep the chimney warm preventing this USINg AgAIN. condensation. continued on next page VGZ-029 / 060209 TR009 PERFORMER™ / Page 15 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 16: Glass Gasket Replacement

    Gasket and Glass cleaning products are available at local retail home centers. Manufacturers of cleaning products include, A.W. Perkins Co. (www.awperkins. com) or Rutland Products (www.rutland.com). continued on next page Page 16 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 17 - tR009 pERFoRmER™ stoVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. 6 (10) 7 (10) 9 (10)
  • Page 18 - tR009 pERFoRmER™ stoVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Ref. Part No. No. Description qty.
  • Page 19 Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem Step 4: Compare Rsystem to Rspecs Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative. VGZ-029 / 060209 TR009 PERFORMER™ / Page 19 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 20 24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Page 20 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 21 VGZ-029 / 060209 TR009 PERFORMER™ / Page 21 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 22 BELIEvES IN HIM SHaLL NoT PERISH BUT HavE ETERNaL LIFE” jOhN 3:16 MADE IN ChINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 22 / TR009 PERFORMER™ VGZ-029 / 060209 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...

Table of Contents