AIR-TIGHT WOODSTOVE
Model TR 001 Owners Manual
READ ALL INSTRUCTIONS CAREFULLY
BEFORE STARTING THE INSTALLATION
OR OPERATING THE STOVE. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT
IN PROPERTY DAMAGE, BODILY INJURY, OR
EVEN DEATH.
NOTE: A LICENSED PROFESSIONAL HEAT-
ING AND COOLING CONTRACTOR SHOULD
BE CONSULTED IF YOU HAVE QUESTIONS
REGARDING THE INSTALLATION OF THIS
SOLID FUEL BURNING APPLIANCE.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS,
RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
VGZ-026 / 20120306.0
HIGH EFFICIENCY
EPA Certified (4.21grams/hr)
(save this manual for future reference)
Vogelzang International Corp.
DO NOT USE THIS STOVE IN A
MOBILE HOME, MANUFACTURED HOME,
TRAILER OR TENT – NO EXCEPTIONS!
This stove meets
U.S. Test Standards:
UL 1482-1996
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
TR001 DEFENDER™ /
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TR001 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vogelzang International TR001

  • Page 1 RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 1 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 2 FLUE SERVING ANOTHER APPLIANCE. of elevating the fire and must not be used. 9. DO NOT CONNECT A WOOD BURNING STOVE Page 2 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...
  • Page 3 Always close the door after ignition. Wood Stoves Safely” NFPA No. HS-10-1978. Write 29. DO NOT CONNECT TO OR USE IN CONJUNC- NFPA, Batterymarch Park, Quincy, MA 02269. Page 3 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 4: Locating Stove

    ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND MATERIALS REQUIRED FOR INSTALLATION TOOLS blower assembly so as not to obstruct air flow. Use four screws provided to fasten the blower to rear heat shield.
  • Page 5: Top View

    AND EXTENDING 2” BEYOND EACH SIDE 35" 12"min 8"min. 41" 17" SIDEWALL FLOOR 16"min. PROTECTOR 15" 23" 6"min. min. Fig. 1 – TOP VIEW Minimum Clearance Dimensions from Combustible Surfaces Page 5 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 6: Firebrick Assembly

    MISSING OR CRACKED FIRE BRICKS! Four (4) A-Size Two (2) B-Size One (1) C-Size Fig. 3a – Front View Minimum Clearance Dimensions from Combustible Surfaces Fig.4a– Step 1, Bottom Firebrick Installation Page 6 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...
  • Page 7: Connector Pipe Installation

    WARNING: DO NOT USE SINGLE WALL may be no more than a maximum of 3˝/76mm apart. CONNECTOR PIPE AS A CHIMNEY - A HOUSE FIRE COULD RESULT. CORRECT WRONG WRONG Fig.5 – Stovepipe/Flue Connections Page 7 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 8: Chimney Connections

    Make repairs before attaching the stove. The con- nector stove pipe and fittings you will need to con- nect directly to a masonry chimney are shown in Fig. 7 - Chimney Construction Through Attic Space figure 6. Page 8 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...
  • Page 9 Fig. 9 - Chimney Connection to Firebox Through Masonry Wall consult a qualified licensed contractor, qualified en- gineer, competent mason, certified Chimney Sweep, Continued on next page Page 9 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 10: Fireplace Installation

    Make sure the thimble is flush with the inner surface of the chimney liner and does not protrude into the flue (see figure 4 on page 6). FIG. 10 - Fireplace Conversion Page 10 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...
  • Page 11 24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Page 11 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 12: Building A Fire

    7. Once fuel has been loaded, close the door and fully OR IN STORAGE. open air inlet control until fire is well established (approximately 10 minutes) being careful not to overfire. Continued on next page Page 12 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...
  • Page 13: Operating Tips

    E X T R E M E LY H O T A N D M AY I G N I T E SURROUNDING MATERIALS. IN CASE OF A CHIMNEY FIRE CALL THE FIRE DEPARTMENT IMMEDIATELY. Page 13 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 14: Chimney Draft

    8. When replacing glass into door, be sure not to objects do not protrude to impact the glass. overtighten screws and clips. 3. Do not build fires against (or that might fall against) Continued on next page the glass. Page 14 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...
  • Page 15: Chimney Maintenance

    SPECTED BY A QUALIFIED EXPERT BEFORE USING AGAIN. A fire in the firebox may be smothered by pouring a large quantity of coarse salt, baking soda, or cool ashes on top of the fire. Page 15 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 16 PARTS - TR001 DEFENDER HIGH-EFFICIENCY STOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. 6 (9) 7 (9) 8 (9)
  • Page 17 PARTS - TR001 DEFENDER HIGH-EFFICIENCY STOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Handle Assembly (complete) ....1 Door Frame ..........
  • Page 18 AND WHENEVER SERVICING BLOWER ASSEMBLY. NOTICE: ANY REPLACE- MENT WIRING MUST HAVE E Q U I VA L E N T I N S U L A - TION AND TEMPERATURE RATING (105°C). Page 18 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...
  • Page 19 Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem Step 4: Compare Rsystem to Rspecs Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative. Page 19 VGZ-026 / 20120306.0 TR001 DEFENDER™ / Vogelzang International Corp.
  • Page 20 “FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT WHOEVER JOHN 3:16 MADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 20 / TR001 DEFENDER™ www.vogelzang.com VGZ-026 / 20120306.0...