Specifying Settings Concerning The Transmission Results For Ip Relay Transmissions (Mode 382) - Konica Minolta SU-501 User Manual

Table of Contents

Advertisement

8
Specifying settings concerning the transmission results for IP relay
transmissions (mode 382)
Specify the length of time until the transmission results for an IP relay
transmission times out and the operation that is performed when a timeout
occurs.
Settings at time of purchase
Bit
Setting
Specifying the setting
During the production of this unit, the settings in the shaded cells were
selected.
Bit
7
6, 5, 4, 3
2, 1, 0
8-24
7 6 5 4 3 2 1 0
0 1 0 0 0 0 0 0 (HEX: 40)
Description
Specifies the opera-
tion that is performed
when the return of
transmission results
for an IP relay trans-
mission times out.
Specifies the length of
time until transmission
results for an IP relay
transmission times
*
out.
--------------------------
Specifying management settings
Setting
Description
0
Transmission error
1
Normal transmission
0000
0 minutes
0001
5 minutes
0010
10 minutes
0011
15 minutes
0100
20 minutes
0101
30 minutes
0110
40 minutes
0111
50 minutes
1000
1 hour
1001
2 hours
1010
3 hours
1011
4 hours
1100
5 hours
1101
6 hours
1110
7 hours
1111
8 hours
000
*Do not change these bits
when specifying setting for
this function.