Kenmore 79045013100 Installation Instructions Manual page 7

30" slide-in electric range

Advertisement

Available languages

Available languages

Where
local codes DO NOT permit
connecting
the appliance-grounding
conductor
to the neutral
(white)
wire, or if
connecting
to 4-wire
electrical
system
(see
Figure 6):
1. Be sure that no power is supplied
on the cable
from residence.
2. Remove the grounding
strap from the terminal
block and from the appliance
frame.
3. in the circuit
breaker,
fuse box or junction
box:
A) Connect
the white appliance
cable wire to
the neutral
(white) wire.
B) Connect
the 2 black wires together.
C) Connect
the 2 red wires together.
D) Connect
the green (or bare copper)
grounding
wire to the grounding
wire of the
circuit
breaker, fuse box or junction
box.
Green
(or Bare Copper)
Wire
Wires
Green
(or Bare Copper)
Wire
Cable from
Residence
Junction
Box
White Wire
(Neutral)
_Black
_
Wires 1
White Wire
(Neutral)
................
_U
L-listed
Cable from
Conduit
Appliance
Connector
(or CSA listed)
Figure 6 - 4-Wlre
Electrical
System
(Example:
Junctian Bax)
Cabinet
Construction
To eliminate
the risk of burns
or fire by reaching
over heated
surface
units, do
not have cabinet
storage
space above the range.
If there is cabinet
storage
space above range,
reduce
risk by installing
a range hood that projects
horizontally
a minimum
of 5" (12.7 cm) beyond
the
bottom
of the cabinet.
Cauntertap
Preparatian
• The cooktop
sides of the range fit over the cutout
edge of your countertop.
• If you have a square finish (fiat) cauntertap,
no
countertop
preparation
is required.
Cooktop
sides
lay directly
on edge of countertop.
• Farmed
frant-edged
cauntertaps
must have
molded
edge shaved fiat 3/4"
(1.9 cm) from
each front corner of opening
(Fig. 7).
• Tile cauntertaps
may need trim cut back 3/4"(1.9
cm) from each front corner and/or
rounded
edge
flattened
(Figure 7).
3_
_
(].9
¢m)
Min.
Width
...... _
31 s/_,,
(79.5 cm)
Formed or tile countertop
trimmed 3A" (1.9 cm) back at
(1 9 c"
" " -rn)
"
-
............
" I
front
corners
of countertop
I
e
opening.
Figure 7
If the existing
cutaut width is greater
than
30 1/16"
(76,4
cm),
reduce
the
3/_"
(1.9 cm)
dimension.
Caunferfap
must be level.
Place a level on the
countertop,
first side to side, then front to back.
if the countertop
is not level, the range will not
be level. The oven must be level for satisfactory
baking
results. Cooktop
sides of range fit over
edges of countertop
opening.
7