Kenmore 79045013100 Installation Instructions Manual page 6

30" slide-in electric range

Advertisement

Available languages

Available languages

Silver colored
Terminal
wi re
Terminal
Block
wire
1-1/8"
Dia.
A strainrelief--
Direct
supplied
by the user
Connection
must be installed
at
To 240 V
Hole.
Punch
this location
receptacle
out knockout
for 1-3/8"
Dia.
Figure 3
Cord KitHole
Four
Conductor
Wire
Connection
to Range
Where
local codes does NOT permit connection
of
the frame
grounding
conductor
to the neutral
wire
of the copper
power supply cord (see Fig. 4)
1. Remove the 3 screws at the lower end of the
rear wire cover, then raise the lower end of the
rear wire cover (access cover) upward
to expose
range terminal
connection
block (see Fig. 2).
2. Remove the ground
strap from the terminal
block
and from the appliance
frame.
&Using
the nuts supplied
in the literature
package,
connect
the ground
wire (green) of copper
power
supply cord to the frame
of the appliance
with
the ground
screw, using the hole in the frame
where the ground
strap was removed
(see Fig. 4).
4.Connect
the neutral
of the copper
power supply
cord to the center silver-colored
terminal
of the
terminal
block, and connect
the other wires to
the outer terminals.
Match
wires and terminals
by
color (red wires connected
to the right terminal,
black wires connected
to the left terminal).
5.Lower the terminal
cover and replace
the 3
screws.
Block
Colored
i
Terminal
Wire
1-1/8"
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box or Junction
Box
If the appliance
is connected
directly
to the circuit
breaker,
fuse box or junction
box, use flexible,
armored
or nonmetallic
sheathed
copper
cable
(with grounding
wire). Supply a U.L listed strain-
relief at each end of the cable.
At the appliance
end, the cable goes through
the Direct Connection
Hole (see Figure 4) on the Cord Mounting
Plate.
Wire
sizes (copper
wire only) and connections
must conform
to the rating
of the appliance.
Where
local codes permit connecting
the
appliance-grounding
conductor
to the
neutral
(white)
wire
(see Figure
5):
1. Be sure that no power is supplied
on the cable
from residence.
2. Remove the grounding
strap from the terminal
block and from the appliance
frame.
3. In the circuit
breaker,
fuse box or junction
box:
A) Connect
the green (or bare copper)
wire,
the white appliance
cable wire, and the neutral
(white) wire together.
B) Connect
the 2 black wires together.
C) Connect
the 2 red wires together.
White Wire
(Neutral)
Cable from
Residence
Black
Wires-
Box
White Wire
(Neutral)
Green
....
U.L.qisted
(or Bare Copper)
Conduit
Wire
Cable from
Connector
Range
(or CSA listed)
Figure 5
3-Wire
(Grounded
Neutral)
Electrical System
(Example:
Junction
Box)
A strainreiief
supplied
by the user
must be installed at
this location
240 V receptacle
NOTE: Be sure to remove the supplied
grounding
strap
Figure 4