Vent Location; Vent Configurations - Travis Industries 31 DVI Owner's Manual

Gas insert
Hide thumbs Also See for 31 DVI:
Table of Contents

Advertisement

16
Installation (for qualified installers only)

Vent Location

A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures
proper combustion for all vent configurations. Depending upon the vent configuration, you may be
required to adjust the restrictor position.
NOTE: Vent location changes based
upon restrictor position. Position # 1 is
shown to the right. Each restrictor
position moves the vent location forward
(toward the fireplace opening)
approximately 1/4".

Vent Configurations

Inlet & Exhaust Re-Line
Exhaust
3" dia.
Gas Liner
Factory Built (Metal) Wood-
Burning Fireplace
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
© Travis Industries
Exhaust (3" Dia.)
6-1/8"
1-1/4"
Direct Vent Cap
6-5/8" to 3" & 3" Colinear
Adapter & Flashing
Inlet
3" dia. Gas Liner
Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.
4100322
Center Line
Inlet (3" Dia.)
2-5/8"
1-1/4"
Exhaust Only Re-Line
Masonry Fireplace
15-1/8"
Fireplace
Opening
Exhaust
3" dia. Gas Liner
Any cracks or
damage inside the
chimney must be
repaired.
A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(non-combustible
materials)
Inlet
100-01235_000