Set Gas Input Rate - Carrier KGANP5201VSP Installation Instructions Manual

Gas convection kit natural-to-propane for variable speed, condensing and non-condensing gas furnace
Table of Contents

Advertisement

back-up w rench ontee when tightening gas inletpipe
plug. (See F ig. 4 6.)
2" Brass Nipple
/
Low Gas
Pressure
Switch
Female x Female x Male Tee
1/8" NPT Pipe Plug ..................................
J
For inlet pressure tap
A11398
Fig. 46 - 80% Low Gas Pressure
Switch
CHECK FURNACE AND MAKE ADJUSTMENTS
FIRE AND EXPLOSION
HAZARD
Failure
to follow
this warning
could result in personal
iniury
and/or death.
NEVER
test for
gas
leaks
with
an open
flame.
Use
a
commercially
available
soap
solution
made
specifically
for
the
detection
of leaks
to check
all connections.
A fire or
explosion
may
result
causing
property
damage,
personal
iniury or loss of life.
RISQUE
D'EXPLOSION
ET D'INCENDIE
Le fait de ne pas suivre cet avertissement
pourrait
entra_ner
des
dommages
corporels
et / ou la mort.
Ne jamais
exanfiner
pour les fuites
de gaz avec une flamme
vive.
Utilisez
plut6t
un
savon
fair specifiquement
pour
la
d_tection
des fuites
de gaz pour verifier
tousles
connections.
Un incendie
ou une explosion
peut entrainer
des dommages
materiels,
des blessures
ou la mort.
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death or property
damage.
Gas
supply
MUST
be
shut
off
before
disconnecting
electrical
power
and proceeding
with conversion.
ELECTRICAL
SHOCK,
FIRE
OR
EXPLOSION
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death or property
damage.
Before
installing,
modifying,
or servicing
system,
main
electrical
disconnect
switch
nmst be in the OFF position
and
install
a
lockout
tag.
There
may
be
more
than
one
disconnect
switch.
Lock out and tag switch with
a suitable
warning
label. Verify proper
operation
after servicing.
1.
2.
3.
4.
5.
6.
7.
GAS
Be sure main gas and electric
supplies
to furnace
are off.
Remove
l/8-in.
(3 ram) pipe plug from manifold
pressure
tap on downstream
side of gas valve.
Attach manometer
to manifold
pressure
tap on gas valve.
Turn gas supply manual
shutoff valve to ON position.
Turn furnace gas valve switch
to ON position.
Check all threaded
pipe connections
for gas leaks.
Turn on furnace
power
supply.
INPUT
RATE
INFORMATION
The gas input rate for propane
is the same as for natural
gas. See
furnace
rating
plate for input
rate. The input
rate for propane
is
deternfined
by manifold
pressure
and orifice size.
The gas valve nmst be set for Low Heat first and then set for High
Heat on 2-stage
and variable-speed
furnaces.
Furnace
gas input
rate on rating
plate is for installations
at altitudes
up to 2000 ft.
(610 M).
In the U.S.A.,
the input rating
for altitudes
above 2000 ft. (610
M) must be reduced
by 2 percent
for each 1000 ft. (305 M) above
sea level.
In Canada,
the input
rating
must
be derated
by 5 percent
for
altitudes
of 2000
ft. (610 M) to 4500
ft. (1372
M) above
sea
level.
The
Conversion
Kit Rating
Plate
accounts
for
high
altitude
derate.
SET GAS INPUT RATE
Burner
Flame
___
Burner>
Al1461
Fig. 47 - Burner Flame
1. Verify SW1-2 on furnace control is turned "ON". See Fig.
45.
2. Jumper R and W/W1 thermostat connections
to call for
heat.
3. Check manifold orifices for gas leaks when main burners
ignite.
4. Adjust gas manifold pressure, (Refer to conversion kit rat-
ing plate 337704-204,
5. Remove caps that conceal adjustment screws for gas valve
regulators, (See Fig. 43.)
24