Carrier KGANP5201VSP Installation Instructions Manual page 8

Gas convection kit natural-to-propane for variable speed, condensing and non-condensing gas furnace
Table of Contents

Advertisement

SW4
Outside
Air Thermistor_
_/F_ Crflntin u;_2pFan_
switches
CF 1 through
CF 3
Communication
_[ SW4
[]
_I=_
PL9
O_
Connocton
24 VAC
HUM Output
(O.5 AMP
i
Setup Switches
SWl,
1 thru 8
_t_ /_:21
_
W2
Yt
DHUM
SW2
'1
SW2 A/C Air Flow
Setup Switches
AC 1 through
AC 3
Fig. 14 - Furnace
Control
Al1471
7. When main burners ignite, confirm inlet gas pressure is
between 11.0-in. W.C. and 13.6-in. W.C.
8. Remove jumper across R-W/W1
and R-W2
thermostat
connections to terminate call for heat.
9. Turn furnace gas valve switch to OFF position.
10. Turn gas supply manual shutoff valve to OFF position.
11. Turn off furnace power supply.
12. Remove manometer.
13. Apply pipe dope sparingly to end of inlet gas pipe plug
and install into unused end of 1/8 in. tee. Use a small
back-up
wrench on tee when tightening gas inlet pipe
plug. (See Fig. 13.)
CHECK
FURNACE
AND MAKE
ADJUSTMENTS
FIRE AND EXPLOSION
HAZARD
Failure to follow this warning could result in personal iniury
and/or death.
NEVER
test for gas leaks with an open flame. Use a
commercially
available soap solution made specifically for
the detection of leaks to check all connections. A fire or
explosion
may result causing property
damage, personal
injury or loss of life.
RISQUE D'EXPLOSION
ET D'INCENDIE
Le fait de ne pas suivre cet avertissement pourrait entrai'nerdes
dommages corporels et / ou la mort.
Ne jamais examiner pour les fuites de gaz avec une flamme
vive. Utilisez plut6t un savon fait specifiquement
pour la
d_tection des fuites de gaz pour verifier tousles
connections.
Un incendie ou une explosion peut entrainer des dommages
matdriels, des blessures ou la mort.
1. Be sure main gas and electric supplies to furnace are off.
2. Remove 1/8-in. (3 mm) pipe plug from manifold pressure
tap on downstream side of gas valve.
3. Attach manometer to manifold pressure tap on gas valve.
(see Fig. 15.)
4. Turn gas supply manual shutoff valve to ON position.
5. Turn furnace gas valve switch to ON position.
6. Check all threaded pipe connections for gas leaks.
7. Turn on furnace power supply.
ON/OFF Switch
MODULATING
/
Min/Max
Heat
Adust
/
(Under
Cap)
Inlet
_Manifold
Pressure
lap
Fig. 15 - Gas Valve
A10496
GAS INPUT
RATE INFORMATION
The gas input rate for propane
is the same as for natural
gas. See
furnace
rating plate on blower
door for input rate. The input rate
for propane
is determined
by manifold
pressure
and orifice size.
The gas valve
must be set for Maximum
Heat first and then set
for Minimum
heat on Modulating
furnaces.
Furnace
gas input
rate on rating
plate is for installations
at altitudes
up to 2000 ft,
(610 M).
In the U.S.A.,
the input rating for altitudes
above 2000 ft. (610M)
must be reduced
by 2 percent
for each 1000 ft, (305 M) above sea
level.
In Canada,
the input
rating
must
be derated
by 5 percent
for
altitudes
of 2000
ft, (610 M) to 4500
ft, (1372
M) above
sea
level.
The
Conversion
Kit Rating
Plate
accounts
for
high
altitude
@rate,

Hide quick links: