ORIFICE
SELECTION/DERATE
[]NIT
DAMAGE
HAZARD
Failure to follow
this caution
may result in unit damage.
DO NOT
re-drill
burner
orifices.
Improper
drilling
may
result in burrs, out-of-round
holes, etc. Obtain new orifices
if orifice size must be changed.
(See Fig. 22.)
In Canada,
the input
rating
must
be derated
by 5 percent
for
altitudes of 2000
ft. to 4500
ft. (610 M to 1372
M) above
sea
level.
The
Conversion
Kit Rating
Plate
accounts
for
high
altitude
derate.
INSTALL
ORIFICES
1. Install
main burner
orifices.
Do not use Teflon tape. Fin-
ger-tighten
orifices
at least
one
full
turn
to prevent
cross-threading,
then tighten with wrench.
2. There
are enough
orifices
in each kit for largest furnace.
Discard
extra orifices.
BURNER
"\
f
ORIFICE
BURNER
ORIFICE
A96249
Fig. 22 - Burner
Orifice
Refer
to conversion
kit rating
plate
337704-206
to determine
main burner
orifice size. (See Fig. 23.)
Furnace
gas input rate on furnace
rating plate is for installations
at
altitudes
up to 2000 ft. (610 M).
In the U.S.A.;
the input rating
for altitudes
above 2000 ft. (610
M) must be reduced
by 2 percent
for each 1000 ft. (305 M) above
sea level.
,f
CONVERSION
KiT
RATING
PLATE
NOTE:
DO NOT reinstall the manifold at this time.
INSTALL
MIXER
SCREWS
NOTE:
There
are
2 sets
of mixer
screws.
One
set is for
Condensing
gas furnaces,
the other set is for Non-condensing
gas
furnaces.
Use only
the parts in the bag marked
"REQUIRED
FOR
THE
CONVERSION
OF
CONDENSING
GAS
FURNACES
TO PROPANE
GAS"
See Fig. 24 to verify you have the correct
set of mixer screws.
1. Locate the dimple
on each burner
venturi
tube. If you can-
not locate the dimple,
refer to Fig. 25 for location
of the
mixer screw.
2. Drill a 7/64-in.
(2.8 mm)
hole (supplied
in kit) in each
dimple.
3. Install
a mixer
screw
in each
drilled
hole
drilling
as
straight
as possible.
The screw head should
be flush with
the top of the burner
venturi.
- CARRIER
CORPORATION
THiS APPLIANCE
HAS
BEEN
CONVERTED
TO USE
PROPANE
GAS
FOR
FUEL.
REFER
TO KiT iNSTRUCTIONS
FOR
CONVERSION
PROCEDURES,
USE PARTS
SUPPLIED
BY CARRIER
CORPORATION
AND
iNSTALLED
BY QUALIFIED
PERSONNEL.
SEE EXiSTiNG
RATING
PLATE
FOR APPLIANCE
MODEL
NO. AND
iNPUT
RATING.
NOTE: Furnace gas input rate on rating plate is for installations up to 2000 ft. (610m) above sea level, in U.S.A. the input rating for altitudes above 2000 ft. (610m) must
be derated by 2% for each 1000 ft. (305m) above sea meveL mnCanada the input rating must be derated by 5% for altitudes of 2000 ft. (610m) to 4.500ft. (1372m) above sea meveL
KiT NO.: KGANP5201VSP
(SUPERSEDES: NONE)
APPLIANCE
MODELS
59TN6A
986TA
PG96VAT
FUELUSED:
PROPANEGAS
NLETPRESSURE(min-max):
11.0-13.61n.wc
ALTITUDE
OF iNSTALLATiON
(FT. ABOVE
SEA LEVEL)
U.S.A.
*
0
2001
*
3001
4001
5001
6001
7001
8001
9001
to 2000
to 3000
to 4000
to 5000
to 6000
to 7000
to 8000
to 9000
to 1OOOO
Orifice 1.25mm
1.25mm 1.25mm 1.25mm
1.25mm 1.25mm 1.25mm
1.25mm
1.25mm
No.
Manifold Pressure
iHIGH
11.o ]11.o [ 11o _11.o I 11o [ 11o [ 11.o [ 11o [ 11.o
LOW
5.8
5.5
5.5
5.5
5.4
5.4
5.4
5.3
5.3
* For Canadian Installations from 2000 to 4500 ft. (610m to 1373m) use U.S.A. column 2001 to 3000 ft. (611m to 914m).
N
337704-206 REV. D
i'
Al1635
Fig. 23 - Conversion
Kit Rating
Plate
[337932=701j
CONTAINS:
QTY
PART #
DESCRIPTION
328456-402
BIT, DRILL
1
FAJ5812B
SCREW
7
REQUIRED
FOR CONVERSION
OF
CONDENSING
GAS FURNACE
TO
PROPANE
GAS.
Fig. 24 - Gas Conversion
Kit
Al1294
13
1.9"
(48.76 mm)
t
1.8"
(46.96 ram)
\\\\\
Fig. 25 - Mixer
Screw
Location
Drill out with
/64"drill bit
Al1460