Carrier KGANP5201VSP Installation Instructions Manual page 16

Gas convection kit natural-to-propane for variable speed, condensing and non-condensing gas furnace
Table of Contents

Advertisement

D'EQUIPEMENT
D'OPERATION
Toute erreur de cfiblage peut _tre une source de danger et de
panne.
Lors des op6rations d'entretien des commandes, 6tiqueter
tous les ills avant de les d6connecter.
1. Disconnect
orange wire from low-heat pressure switch
LPS on inducer housing.
2. Connect the orange wire from the Low Heat Pressure
Switch to the orange wire with the insulated male spade
terminal.
3. Connect the orange wire from the Low Gas Pressure
Switch to the terminal on the Low Heat Pressure Switch.
4. Route orange wires along wire harness. If possible, secure
with wire tie provided in kit.
CHECK
INLET
GAS PRESSURE
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
DO NOT operate furnace more than one minute to check
inlet gas pressure, as conversion is not complete at this time.
NOTE:
This kit is to be used only when
inlet gas pressure
is
between
ll.0-in.
W.C. and 13.6-in.
W.C.
1. Verify manometer
is connected
to inlet pressure
tap on gas
valve.
2. Turn on furnace
power
supply.
3. Turn gas supply manual
shutoff valve to ON position.
4. Turn furnace gas valve switch
to ON position.
5. Turn
Setup
Switch
SWI-2
on furnace
control
ON (see
Fig. 31).
6. Jumper
R-W/W1
and R-W2
thermostat
connections
on
control.
7. When
main
burners
ignite,
confirm
inlet
gas pressure
is
between
ll.0-in.
W.C. and 13.6-in.
W.C.
8. Remove
jumper
across
R-W/WI
and R-W2
thermostat
connections
to terminate
call for heat.
9. Turn furnace gas valve switch
to OFF position.
10. Turn gas supply manual
shutoff valve to OFF position.
11. Turn off furnace
power
supply.
12. Remove
manometer.
13. Apply
pipe dope sparingly
to end of inlet gas pipe plug
and install
into unused
end of 1/8 in. tee. Use a small
back-up
wrench
on tee when
tightening
gas inlet
pipe
plug. (See Fig. 13.)
CHECK
FURNACE
AND
MAKE
ADJUSTMENTS
FIRE AND EXPLOSION
HAZARD
Failure
to follow
this warning
could result in personal
iniury
and/or death.
NEVER
test for
gas
leaks
with
an open
flame.
Use
a
commercially
available
soap
solution
made
specifically
for
the
detection
of leaks
to check
all connections.
A fire or
explosion
may
result
causing
property
damage,
personal
injury or loss of life.
RISQUE
D'EXPLOSION
ET D'INCENDIE
Le fait de ne pas suivre cet avertissement
pourrait
entra_ner
des
dommages
corporels
et / ou la mort.
Ne jamais
examiner
pour les fuites
de gaz avec une flamme
vive.
Utilisez
plut6t
un
savon
fair specifiquement
pour
la
d_tection
des fuites
de gaz pour verifier
tous les connections.
Un incendie
ou une explosion
peut entrainer
des dommages
materiels,
des blessures
ou la mort.
SW4
Outside
Air Thermistor_
_F_
Crflnotiwn U ;_uSpFa n_
switches
CF 1 through
CF 3
Communication
_I_ SW4
[]
_I=_PL9
O_
Connect
on--
24 VAC
HUM Output
(O.5AMP
32
Setup Switches
SWl,
1 thru 8
ModelPlug ____
_-I[1 _'!_i
I_]_
/_
/_:21
_
W2
Yt
DHUM
SW2
'1
SW2 A/C Air Flow
Setup Switches
AC 1 through
AC 3
Fig. 31 - Furnace
Control
Al1471
FIRE,
EXPLOSION,
ELECTRICALSHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death or property
damage.
Gas
supply
MUST
be
shut
off
before
disconnecting
electrical
power
and proceeding
with conversion.
ELECTRICAL
SHOCK,
FIRE
OR
EXPLOSION
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death or property
damage.
Before
installing,
modifying,
or servicing
system,
main
electrical
disconnect
switch
must be in the OFF position
and
install
a
lockout
tag.
There
may
be
more
than
one
disconnect
switch.
Lock out and tag switch with
a suitaMe
warning
label. Verify proper
operation
after servicing.
16