Carrier KGANP5201VSP Installation Instructions Manual page 18

Gas convection kit natural-to-propane for variable speed, condensing and non-condensing gas furnace
Table of Contents

Advertisement

SECTION
3
Table
4 - Non-condensing
Furnaces
MODEL NUMBERS
BEGINNING
WITH:
58CVA
315AAV
58CVX
315JAV
PG8MVA
PG8JVA
INSTALLATION
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death or property
damage.
Gas
supply
MUST
be
shut
off
before
disconnecting
electrical
power
and proceeding
with conversion.
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK
AND
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to follow
instructions
could result in personal
injury,
death or property
damage.
Improper
installation,
adjustment,
alteration,
service,
maintenance,
or use can cause carbon
monoxide
poisoning,
explosion,
fire, electrical
shock,
or other conditions,
which
could
result
in personal
injury
or death.
Consult
your
distributor
or branch
for
information
or assistance.
The
qualified
installer
or
agency
must
use
only
factory-authorized
kits or accessories
when
servicing
this
product.
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK,
AND
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to follow
this warning
could
result
in personal
injury or death.
This conversion
kit shall be installed
by a qualified
service
agency
in accordance
with the manufacturer's
instructions
and all applicable
codes
and requirements
of the authority
having
jurisdiction.
If the information
in these instructions
is not followed
exactly,
a fire, explosion,
or production
of
carbon
monoxide
could
result
causing
property
damage,
personal
injury,
or loss of life. The qualified
service
agency
is responsible
for the proper
installation
of this furnace with
this kit. The installation
is not proper
and complete
until the
operation
of the converted
appliance
is checked
as specified
in the manufacturer's
instructions
supplied
with the kit.
LE FEU, L'EXPLOSION, CHOC ELECTRIQUE,
ET MONOXYDE
DE CARBONE
EMPOISONNER
Cette trousse de conversion
doit Otre installOe par un servie
d'entretien
qualifiO,
selon
les instructions
du fabricant
et
selon
routes
les exigences
et tousles
codes
pertinents
de
l'autoritO
compOtente.
Assurezvous
de
bien
suivre
les
instructions
dans cette notice
pour rdduire
au minimum
le
risque
d'incendie,
d'explosion
ou
la
production
de
monoxyde
de
carbone
pouvant
causer
des
dommages
matOriels,
de blessure
ou la mort.
Le service
d'entretien
qualifiO
est responsable
de l'installation
de cette trousse.
L'installation
n'est pas adOquate ni complOte
rant que le bon
fonctionnement
de l'appereil
converti
n'a
pas OtO vOrfiO
selon les instructions
du fabricant
fornies
avec la trousse.
1. Set room thermostat to lowest setting or "OFF".
2. Remove outer doors.
3. Disconnect power at external disconnect, fuse or circuit
breaker.
4. Turn off gas at external shut-off or gas meter.
5. Remove outer doors and set aside.
6. Turn electric switch on gas valve to OFF.
MANIFOLD/ORIFICE/BURNER
REMOVAL
[]NIT
OPERATION
HAZARD
Failure to follow this caution may result in unit damage or
improper operation.
Label all wires prior to disconnection
when servicing
controls.
D'EQUIPEMENT
D'OPERATION
Toute erreur de cfiblage peut _tre une source de danger
et de
panne.
Lors des op6rations
d'entretien
des commandes,
6tiqueter
tousles
ills avant de les d_connecter.
NOTE:
Use a back-up
wrench
on the gas valve
to prevent
the
valve from rotating
on the manifold
or damaging
the mounting
to
the burner box. See Fig. 33 and 34.
1. Disconnect
the gas pipe from
gas valve
and remove
pipe
from the furnace
casing.
2. Disconnect
the connector
harness
from gas valve. Discon-
nect wires
from
Hot
Surface
Igniter
(HSI)
and
Flame
Sensor.
3. Support
the manifold
and remove
the 4 screws
that secure
the manifold
assembly
to the burner
box and set aside.
4. Note the location
of the green/yellow
wire ground wire for
re-assembly
later.
5. Remove
wires from both rollout switches.
6. Slide
one-piece
burner
assembly
out of slots on sides of
burner box.
7. Remove
the flame sensor from the burner
assembly.
8. Remove
the orifices
from the manifold
and discard.
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents