Fire And Explosion Hazard - Carrier KGANP5201VSP Installation Instructions Manual

Gas convection kit natural-to-propane for variable speed, condensing and non-condensing gas furnace
Table of Contents

Advertisement

FIRE AND EXPLOSION
HAZARD
Failure
to follow
this warning
could result in personal
injury
and/or death.
NEVER
test for
gas
leaks
with
an open
flame.
Use
a
commercially
available
soap
solution
made
specifically
for
the
detection
of leaks
to check
all connections.
A fire or
explosion
may
result
causing
property
damage,
personal
injury or loss of life.
RISQUE
D'EXPLOSION
ET D'INCENDIE
Le fair de ne pas suivre cet avertissement
pourrait
entra_ner
des
dommages
corporels
et / ou la mort.
Ne jamais
examiner
pour les fuites
de gaz avec une flamme
vive.
Utilisez
plut6t
un
savon
fair specifiquement
pour
la
d6tection
des fuites
de gaz pour verifier
tousles
connections.
Un incendie
ou une explosion
peut entrainer
des dommages
mat6riels,
des blessures
ou la mort.
MODIFY PRESSURE SWITCH WIRING
UNIT
OPERATION
HAZARD
Failure
to follow
this caution
may result in unit damage
or
improper
operation.
Label
all wires
prior
to
disconnection
when
servicing
controls.
D'EQUIPEMENT
D'OPERATION
Toute erreur de cfiblage peut _tre une source de danger
et de
panne.
Lors des op6rations
d'entretien
des commandes,
6tiqueter
tousles
fils avant de les d6connecter.
1. Locate the orange wire in the kit with an insulated
straight
female
spade
terminal
and an insulated
straight
male
ter-
minal on the other end.
2. Connect
the female
terminal
to a terminal
on the Low Gas
Pressure
Switch.
3. Locate the orange wire in the kit with an insulated
straight
female spade terminal
and an insulated
female flag termin-
al on the other end.
4. Connect
both straight female
terminals
of the orange
wires
to the terminals
on the Low Gas Pressure
Switch.
5. Disconnect
orange
wire
from
low-heat
pressure
switch
LPS on inducer
housing.
6. Connect
the orange
wire
from
the
Low
Heat
Pressure
Switch
to the orange
wire with
the insulated
male
spade
terminal.
7. Connect
the
orange
wire
from
the
Low
Gas Pressure
Switch
to the terminal
on the Low Heat Pressure
Switch.
8. Route orange
wires along wire harness.
If possible,
secure
with wire tie provided
in kit.
CHECK
INLET
GAS
PRESSURE
SW4
Outside
Air Thermi,'
SW3 Continuous
(CF) airflow
setup
switches
CF 1 through
CF 3
_-_--_
Communication
24 VAC
HUM Output
(O.5AMP
in
SW4
[]
_I=_
PL9
O_
Connection
" P,7 ABeD
,
._<
_
SW3
Model Plug_
g__ _i_:_ _11_')11_,_11(\_11
/_21
_
W2
Yt
DHUM
SW2
Setup Switches SWl,
1 thru 8
SW2 A/C Air Flow
Setup Switches
AC 1 through AC 3
Al1471
Fig. 45 - Furnace
Control
[]NIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
DO NOT operate furnace more than one minute to check
inlet gas pressure, as conversion is not complete at this time.
NOTE:
This kit is to be used only when
inlet gas pressure
is
between
ll.0-in.
W.C. and 13.6-in.
W.C.
1. Verify manometer
is connected
to inlet pressure
tap on gas
valve.
2. Turn on furnace
power
supply.
3. Turn gas supply manual
shutoff valve to ON position.
4. Turn furnace gas valve switch
to ON position.
5. Turn
Setup
Switch
SWI-2
on furnace
control
ON (see
Fig. 45).
6. Jumper
R-W/WI
and R-W2
thermostat
connections
on
control.
7. When
main
burners
ignite,
confirm
inlet
gas pressure
is
between
ll.0-in.
W.C. and 13.6-in.
W.C.
8. Remove
jumper
across
R-W/WI
and R-W2
thermostat
connections
to terminate
call for heat.
9. Turn furnace gas valve switch
to OFF position.
10. Turn gas supply manual
shutoff valve to OFF position.
11. Turn off furnace
power
supply.
12. Remove
manometer.
13. Apply
pipe dope sparingly
to end of inlet gas pipe plug
and install
into unused
end of 1/8 in. tee. Use a small
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents