Burner Assembly - Carrier KGANP5201VSP Installation Instructions Manual

Gas convection kit natural-to-propane for variable speed, condensing and non-condensing gas furnace
Table of Contents

Advertisement

1337932-701]
CONTAINS:
QTY
PART #
DESCRIPTION
328456-402
BIT, DRILL
1
FAJ5812B
SCREW
7
REQUIRED
FOR CONVERSION
OF
CONDENSING
GAS FURNACE TO
PROPANE GAS.
Fig. 6 - Gas Conversion
Kit
A11294
2-in.
(50 mm)
3/16-
in.
(4.6 mm)
_
/32 -in.,
+1/32
-3/64-in.
(2.5 mm,
+0.8-1.5)
A12392
Fig. 9 - Igniter
Position
- Side View
CONVERT
GAS VALVE
1.9"
(48.76 mm)
1.8"
(46.96
ram)
Drill out with
J
7/64" drill bit
ii /
\\\\
A11460
Fig. 7 - Mixer
Screw
Location
REINSTALL
BURNER
ASSEMBLY
To reinstall burner assembly:
1. Attach flame sensor to burner assembly.
2. Insert one-piece burner in slot on sides of burner box and
slide burner back in place.
3. Reattach HSI wires to HSI.
4. Verify igniter to burner alignment. See Fig. 8 and 9.
, ,Oo
II
I
-2-1/2-in.
(64.4)
Fig. 8 - Igniter
Position
- Top View
A11405
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK
HAZARD
Failure to follow this warning
could result in personal
iniury, death or property damage.
Gas supply
MUST
be
shut off before
disconnecting
electrical power and proceeding with conversion.
ELECTRICAL
SHOCK,
FIRE
OR
EXPLOSION
HAZARD
Failure to follow this warning
could result in personal
iniury, death or property damage.
Before installing, modifying,
or servicing
system, main
electrical disconnect switch must be in the OFF position and
install
a lockout
tag. There may be more
than one
disconnect switch. Lock out and tag switch with a suitable
warning label. Verify proper operation after servicing.
Refer to Fig. 10 and 11.
Fig. 10 - Propane
Jumper
A11373

Hide quick links:

Advertisement

Table of Contents
loading