End Diffuser Assembly - L.B. White TS080 Owner's Manual And Instructions

Circulating tent heaters
Table of Contents

Advertisement

END DIFFUSER ASSEMBLY

Accessory Part # 21177
1. Insert collar into duct. Tabs of collar must be facing
away from duct. See Fig. 5.
2. Wrap the duct clamp around duct and collar. Saddle
of clamp lays over duct coil. Connect clamp ends
together and tighten securely. See Fig. 5.
FIG. 5
CLAMP
CONNECTING REGULATOR TO PROPANE GAS
(Accessory)
ATTENTION
Only use the regulator supplied with the heater.
The heater must be regulated at all times for proper
operation.
1. Remove the proetive cap from the POL assembly, but
do not discard it. Insert POL stem into the valve on
the cylinder. Thread the nut counterclockwise into
the tank valve. Tighten securely with a wrench. See
Fig. 7.
FIG. 7
POL FITTING
REGULATOR VENT
DIRECTED DOWN
14
3. Insert tabs of collar into slots at air inlet of diffuser.
Push down to lock in place.
4. Tent side wall material may be layed within channel of
the diffuser to give a finished look to the installation.
See Fig. 6 for typical installation.
FIG. 6
2. Slowly open the cylinder valve. This will prevent lock-
up of the excess flow valve built within POL stem.
3. Check all connections with approved leak detector.
Do NOT use flame to check for leaks. A fire or
explosion may result.
4. When storing or transporting the heater, ensure the
cap is pushed back onto the POL fitting. This will
protect the fitting from nicks or other damage and
prevent the entry of moisture.
CYLINDER VALVE
TENT SIDE WALL
MATERIAL LAID
TENT DRAPED
WITHIN DIFFUSER CHANNEL
WITHIN DIFFUSER
CHANNEL
OPTIONAL AIR DIFFUSER

Advertisement

Table of Contents
loading

Table of Contents