Make sure the ColorCommand fixture cannot be rotated all the way around (360
Allowing a unit to rotate 360
Note: Because of the variety of conceivable lighting designs, you should consider the
procedure below as a suggested guideline only. High End Systems, Inc. cannot
make specific recommendations for your particular lighting design or venue.
Before mounting the ColorCommand fixture, heed the warnings below to guard against
personal injury and damage to the fixture.
Warning: This equipment for connection to a branch circuit having a maximum
overload protection of 20 A.
Class I Equipment - This fixture must be earthed.
Mount the power supply and fixtures in a location that is away from
direct heat and protected from moisture. Do not mount on a flammable
surface.
For pluggable equipment, the socket outlet shall be installed near the
equipment and shall be easily accessible.
Use a secondary safety cable when mounting the fixtures.
Caution: Do not remove top cover of the ColorCommand fixture or attempt to
service unit while attached to rigging or truss.

Mounting a ColorCommand Fixture

To mounta ColorCommand fixture to a truss or another type of support:
Attach a suitable clamp through one of the holes on top of the yoke. If you are
attaching one clamp, use the middle hole on the yoke. If you are attaching 2 clamps
per fixture, attach one clamp to each of the outer holes on the yoke. Use two locking
washers per clamp when attaching the clamp to the yoke.
Always stand on a firm, stable surface when mounting a fixture to its support. The
fixture should be at a height where you can comfortably work on it, and should
either be resting on a stable surface or held in a stable manner.
Tighten the clamp(s) firmly to the yoke and to the support.
Loop one or more suitable safety cables around the support and the yoke.
Caution:
After mounting the fixtures, inspect all connected cables to ensure
that the cables are properly routed away from any hot surface.
Do not mount ColorCommand above or next to a hot fixture closer
than 1 ft (.3 m).
B-4
ColorCommand Installation
o
could loosen the clamp mounting bolts.
Dichroic Theatre™ User Manual