Reconfigurating The Colorpower Link; Mounting The Colorpower™ Supply - High End Systems Dichroic Theatre Series User Manual

Dichroic theatre series
Table of Contents

Advertisement

this procedure do not automatically change if a unit fails or is
disconnected.

Reconfigurating the ColorPower Link

If you have a full complement of 12 Dichroic Theater fixtures attached to ColorPower
and change the ColorPower link configuration, you will have to do the following:
1. After changing the link configuration, apply power to the ColorPower.
2. Auto address the fixtures [to clear the old fixture configuration].
3. Reset ColorPower by issuing a home all command, or navigating to C T R L - >
R S T on the ColorPower menu system.
4. Auto address the fixtures a second time [to store the new configuration]. The
fixtures will now operate properly.
Mounting the ColorPower
This section describes mounting procedures for a ColorPower supply. For
information on mounting ColorCommand™ fixtures, see Appendix B. For
information on mounting Source Four™ fixtures fitted with ColorMerge™ modules,
consult the documentation for your Source Four fixture.
You can mount the ColorPower supply in any orientation suspended from a support
system (such as a truss) or freestanding on a stable surface. Before mounting the
ColorPower supply and any fixtures you are connecting to it, heed the warnings
below to guard against personal injury and damage to the fixture.
Warning: This equipment for connection to a branch circuit having a
maximum overload protection of 20 A.
Class I Equipment - This fixture must be earthed.
Mount the ColorPower supply and fixtures in a location that is away
from direct heat and protected from moisture. Do not mount on a
flammable surface.
For pluggable equipment, the socket outlet shall be installed near
the equipment and shall be easily accessible.
Use a secondary safety cable when mounting the ColorPower
supply or fixtures.
Caution: Do not remove top cover of the ColorPower supply or attempt to
service unit while attached to rigging or truss.
When mounting the ColorPower supply or any fixture connected to it on a truss or
another type of support, do all of the following:
Dichroic Theatre™ User Manual
Supply
Setup and Configuration