Explosion Hazard
Use a new AGA approved gas supply line.
Failure to do so can result in death,
explosion, or fire.
Observe all governing codes and ordinances.
This installation must conform with all local codes
and ordinances. In the absence of local codes,
installation must conform with American National
Standard, National Fuel Gas Code ANSI Z223.1 --
latest edition**.
Input ratings shown on the model/serial rating plate
are for elevations up to 2,000 feet. For assistance when
installingthe range at higher elevations, contact your
local Sears Service Center.
Type of gas: This range is design-certified by the
American Gas Association (A.G.A.) for use with
Natural gas or, after proper conversion, for use with
L. P. gas. This range is factory set for use with Natural
gas. Gas conversion instructionsare provided on
Pages 22-29. The model/serial rating plate located on
the frame behind the storage drawer has information
on the types of gas that can be used. If the types of
gas listed do not include the type of gas available,
check with the local gas supplier.
Conversion must be done by a qualified service
technician.
Gas supply line: Provide a gas supply line of 3/4" rigid
pipe to the range location. With L.P. gas, piping or
tubing size can be 1/2" minimum. A smaller size pipe
on longer runs may result in insufficient gas supply.
Usually, L.P. gas suppliers determine the size and
materials used in the system.
Pipe-joint compounds made for use with L.P. gas must
be used on pipe threads only.
Peligro de explosibn
Use una linea de suministro de gas nueva
aprobada por AGA.
No seguir esta instruccibn puede ocasionar la
muerte, una explosibn o un incendio.
Observe todos los c6digos y reglamentos vigentes.
Esta instalacibn debe cumplir con todos los codigos y
reglamentos locales. A falta de cSdigos locales, la
instalaci6n debe cumplir con American National
Standard, National Fuel Gas Code ANSI Z223.1--_ltima
edici6n**.
Las clasificaciones de entrada que se indican en la
placa de modelo/serie
son para elevaciones
de hasta
2,000 pies sobre el nivel del mar. Para asistencia
cuando
instale la cocina en ]ugares con mayor altitud,
contacte
a su Centro de Servicio
Sears.
Tipo de gas: el diseEo de esta cocina ha sido
certificado
por la American
Gas Association
(A.G.A.)
para uso con gas Natural o, despues de la debida
conversi6n,
para uso con gas de P.L. Esta cocina ha
sido ajustada en la fabrica para uso con gas Natural.
Las instrucciones
de conversi6n
de gas aparecen
en
las paginas 22-29. La placa de modelo/serie
ubicada en
el marco detras de] cajSn de aimacenamiento
o la
puerta de] homo, contiene
informaci6n sobre el tipo
de gas que se puede usar. Si los tipos de gas
indicados
no incluyen
con el tipo de gas disponibie,
contacte
a la compaEia
de gas de su Iocalidad.
La conversion debe set hecha pot un tdcnico de servicio
calificado.
Unea de suministro de gas: instale una linea de
suministro
de gas de tubo rigido de 3/4" hasta ]a cocina.
Para el gas de P.L., el tubo debe medir un minimo de 1/2,".
Un tubo mas peque5o para recorridos
mas largos, podrla
ocasionar un suministro
de gas insuficiente. Usualmente,
las compaEia
proveedoras de gas de P.L determinan
las
dimensiones
y los materiales usados en e] sistema.
10
manualshutoffvalve"open" position
v_lvulade cierramanualenla
posici6n"abierta" _
to range
_..J_ _'_\
\
gas supp,,,/
-- ,,-- d .27,,,ro
degas
Flexible metal appliance connector: If local codes
permit, a new A.G.A. design-certified, 1/2" or 3/4" I.D.,
flexible metal appliance connector is recommended
for connecting range to the gas supply line. A 1/2"
male pipe thread nipple is needed for connection to
the female pipe threads of the inlet to the appliance
pressure regulator. Do Not kink or damage the flexible
metal tubing when moving the range.
Rigid pipe connection: Requires a combination of pipe
fittings to obtain an in-line connection to the range. All
strains must be removed from the supply and fuel
lines so range will be level and in line.
Shutoff valve: The supply line must be equipped with
a manual shutoff valve. This valve should be located in
the same room asthe range and should be in a
location that allows ease of opening and closing. The
valve is for turning on or shutting off gas to the range.
Do Not block accessto shutoff valve.
Pressure regulator: The gas pressure regulator
supplied with this range must be used. The inlet
pressure to the regulator should be as follows for
proper operation:
NATURAL GAS:
Minimum pressure: 5 inches WCP
Maximum pressure: 14 inches WCP
L.P. GAS:
Minimum pressure: 11 inches WCP
Maximum pressure: 14 inches WCP
Contact local gas supplier if you are not sure about the
inlet pressure.
Line pressure testing above 1/2 psi gauge
(14" WCP) -- The range and its individual manual
shutoff valve must be disconnected from the gas
supply piping system during any pressure testing
of that system at test pressures greater than
1/2 psig (3.5 kPa).
Line pressure testing at 1/2 psi gauge
(14" WCP) or lower -- The range must be isolated
from the gas supply piping system by closing its
individual manual shutoff valve during any pressure
testing of that system at test pressures equal to or less
than 1/2 psig (3.5 kPa).
Copies of the standards listed may be obtained from:
**American Gas Association
1515 Wilson Boulevard
Arlington, Virginia 22209
Los compuestos para juntas de tubo disebados para uso
con gas de P.L. deben usarse L_nicamente en las roscas
del tubo.
Conector de electrodomdsticos de metal flexible: si los
cSdigos locales Io permiten, se recomienda usar un
conector de electrodomesticos de metal flexible con
diametro intemo de 1/2" 5 3/4", con diseSo certificado por
la A.G.A., para conectar la cocina a ]a linea de suministro
de gas. Se necesita una boquilla acopladora macho de
1/2" para ]a conexiSn a la rosca de tuberia hembra de]
regulador de presiSn. AI mover la
cocina,
no enrosque ni
da_e el tubo de metal flexible.
Conexion con tubo rigido: requiere de una combinaci6n
de accesorios para tubos para ]ograr una conexiSn en la
linea a la cocina. Deben eliminarse las deformaciones
de
las lineas de suministro
y combustible
para que la cocina
este nivelada yen linea.
Valvula de cierre: la linea de suministro
debe estar
equipada
con una valvula de cierre manual.
Esta
valvula debe estar Iocalizada en la misma
habitaciSn
en que esta la cocina, en un lugar que facilite su
apertura
y cierre. El prop6sito de la valvula es generar
o [nterrumpir el suministro
de gas a la cocina. No
bloquee el acceso a la valvula de suministro.
Regulador de presi6n: se debe usar el regulador
de
presi6n provisto
con esta cocina. Para el debido
funcionamiento
de la cocina, la presiSn de entrada al
regulador
debe set como sigue:
GAS NATURAL:
Presi6n minima:
5 pulgadas
WCP
Presi6n maxima:
14 pulgadas
WCP
GAS de P.L:
Presi6n minima:
11 pulgadas
WCP
Presi6n maxima:
14 pulgadas
WCP
Si no esta seguro sobre la presiSn de entrada,
consulte
con la compaf_ia de gas de su Iocalidad.
Prueba de presion de linea a presiones superiores a
1/2 psig (14" WCP)--
La cocina y su vaIvula de cierre
manual se deben desconectar
del sistema
de tuberia
de suministro
de gas durante cualquier
prueba de
presiSn de ese sistema a presiones
de prueba
superiores
a 1/2 psig (3.5 kPa).
Prueba de presion de linea a presiones de 1/2 psig
(14" WCP) o inferiores--
La cocina se debe aislar del
sistema
de tuberia de suministro
de gas cerrando
su
valvula de cierre manual
individual
durante cualquier
prueba de presi6n de ese sistema
a presiones de
prueba de 1/2 psig (3.5 kPa) o inferiores.
Se pueden obtener
coplas de los est&ndares
[ndicados de:
**American Gas Association
1515 Wilson Boulevard
Arlington, Virginia 22209
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

6657577589166575779891

Table of Contents