Performing A Factory Reset; Sender Unit; Receiver Unit - Gefen EXT-DVIKVM-LAN User Manual

Dvi kvm over ip
Hide thumbs Also See for EXT-DVIKVM-LAN:
Table of Contents

Advertisement

Operating the DVI KVM over IP

Performing a Factory Reset

To reset a DVI KVM over IP Sender and / or Receiver unit to factory-default settings, follow
the instructions below.
1.
Disconnect the power from the Sender unit.
2.
Press and hold the Mode button.
While continuing to press the Mode button, reconnect the power.
3.
4.
Continue holding the Mode button until both Power and Link indicators begin
to flash.
5.
Use the end of a paper clip or other sharp pointed device to press the Reset button.
After the Power LED indicator stops flashing, the unit will be ready for use.
6.
1.
Disconnect the power from the Sender unit.
2.
Press and hold the Switch button.
3.
While continuing to press the Switch button, reconnect the power.
Continue holding the Switch button until both Power and Link indicators begin
4.
to flash.
5.
Use the end of a paper clip or other sharp pointed device to press the Reset button.
6.
After the Power LED indicator stops flashing, the unit will be ready for use.

Sender Unit

Receiver Unit