12-MAINTENANCE AND CLEANING

PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN

CLEANING THE EXCHANGER AND PIPE UNIT

CLEANING THE UPPER COMPARTMENT

When the boiler is cold lift front cover "H", remove screws "O" to the right and left and remove cover "A". Then remove the the fixing screws
from drivers "V" and remove boiler cover "B".
At this point, remove the four turbulators "C" and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators,
removing all of the accumulated ash.
Check the cover gasket and replace it if necessary.