4-INSTALLATION AND ASSEMBLY
REQUIREMENTS FOR SYSTEM INSTALLATION
•
the minimum distance in front of the product to allow for cleaning, maintenance, etc. must be at least 1000 mm;
the minimum admitted distance between the rear of the product and the wall must be 400 mm;
•
•
the minimum distance between the upper part of the product and a wall (ceiling) must be of 400 mm to ensure easy access for heat
exchanger cleaning and maintenance (for example to remove ashes);
the minimum distance between the side product and wall must be 300 mm.
•
It is essential to make ventilation holes connecting to the exterior and in compliance with Standard UNI 10683, with the following
characteristics:
1.
They must be made at a height close to that of the floor;
2.
They must be adequately protected by wire mesh or grille, provided it does not reduce the minimum passage section;
3.
They must be positioned in such a way as not to be clogged.
Technical Dept. - All rights reserved - Reproduction is prohibited
19