Installation Instructions; Installing Or Replacing The Lamp - Elation DESIGN SPOT 575E User Manual

Professional moving head
Hide thumbs Also See for DESIGN SPOT 575E:
Table of Contents

Advertisement

persons not qualified for operating the device. Most damages are the result of unprofessional
operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden.
If this device will be operated in any way different to the one described in this manual, the product may
suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to
short-circuit, burns, electric shock, lamp explosion, crash, etc.

INSTALLATION INSTRUCTIONS

a) Installing or replacing the lamp
Do not install lamps with a higher wattage. They generate higher temperatures than which the device
was designed for.
For the installation, you need one MSR GOLD 575 SA/2 DE lamp
Procedure :
1) Unscrew the 4 screws marked A, B, C and D on the back of the housing, holding the plate where the
lamp is underneath.
2) Gently pull the socket holder of the lamp housing in the middle.
3) Carefully insert the lamp into the socket. Please remember there is only one way to insert the lamp.
Gently slide the lamp and its lamp holder back into place and fasten the 4 screws.
4) On the access plate there are 3 small screws marked 1, 2 and 3. which are used to adjust the lamp
holder in the lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get
the maximum light output as shown below.
Please remember the lamp is not a hot-restrike type, you must wait for approximately 10
minutes after having turned off the lamp before you can turn it back on again.
1
2
3
- 5 -
B
A
D
C
V1.0 01NR