Installing The Remote Switch
The H-Series BF's gas valve, located behind the lower trim, may be
connected to a wall switch. The valve generates its own power on a
millivolt circuit. Use only low voltage wire, and DO NOT connect
any external power to it.
Refer to Figure 30 for wiring requirements.
Note: The switch location must not exceed 30' from the fireplace.
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in Figure 7. Side wall clearances are 3".
Combustible surrounds may be installed with 3" clearance to the side
of the fireplace as shown in Figure 8.
Fireplace Facing
When selecting the finish material for your fireplace, it is important to
remember the following: THE PERFORATED VALVE COVER MUST
NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air
supply for the control compartments and heat exchanger it also
prevents access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.
Figure 7. Combustible mantles and facings.
Part No. XG0145
Installation
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Warning:
When covering the upper metal portion of the fireplace with a non-
combustible material Please Note: The decorative facing materials
may be subject to temperatures in excess of 250° F. This should be
considered when selecting facing materials.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures. This can cause melting, deformation,
discoloration or premature failure of T.V. and radio components.
Painting:
Special care is recommended by the Master Painters and Decorators
Association, when painting the fireplace surrounds, to select and apply
a quality Alkyd sealer prior to the applying of latex paints. This is to
prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.