Operation

Lighting Instructions
See pages 19 and 20.
Burner Adjustment
The H-Series BF is equipped with an adjustable burner, allowing you
to raise or lower the flames. To adjust the flames, locate the black knob
Pilot Assembly
marked 'Hi-Lo', in the centre of the gas control valve (See Figure 16).
The front burners are not adjustable.
To raise the flame height, turn the black knob (located behind the
lower trim) counter-clockwise.
To lower the flame height, turn clockwise.
'Hi-Lo' Adjustment Knob
Emergency
Battery
Power
(4 x AA)
Gas Control Knob
(Shown in "Pilot" postion.)
Figure 16a. 'Hi-Lo' Adjustment on the H-Series BF's gas valve.
Wall Switch (SWI)
Manual
Hi/Lo
Main Gas Output
Figure 16b. 'Hi-Lo' Adjustment on the H-Series BF-A's gas valve.
Note: H-Series BF-I models (electronic ignition) do not
feature hi/lo adjustment.
CAUTIONS
Fireplace gas control must be in the "OFF" position
and pilot and main burners extinguished when cleaning
appliance with a vacuum.
Doors and logs can get very hot. Handle only when
cool.
Part No. XG0145
POWER
6VAC 200mA
AC ADAPTOR
Red
Red
Black
Black
Brown
Brown
Green
Orange
Main
Pilot
Main Gas Input
Have the fireplace and installation inspected yearly. The inspection
must include, but is not limited to, the following:
A visual check of the entire vent system and termination.
An inspection of the explosion relief flappers and the door
gasketing to ensure a proper seal.
An inspection of the burner, venturi, and primary air openings.
White (Sensor)
An inspection of the gas valve, gas components, and pilot flame.
Orange (Igniter)
For your convenience a 1/8" manifold pressure tap is supplied
on the gas valve for a test gauge connection. See Figure 32.
Ensure proper log placement as per this manual.
Inspection of all optional equipment; fans, thermostats, etc.
For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For Propane Gas this appliance requires a minimum inlet pressure
Control
of 11" W.C. and a manifold pressure of 10" W.C.
Module
Always keep the fireplace area clear and free of combustible materials,
as well as gasoline and other flammable vapors and liquids.
Do not use this appliance if any part has been under water. Immediately
IPI
call a qualified service technician to inspect the appliance and to
replace any part of the control system and any gas control which
has been under water.
Black
White
When the fireplace is first activated, there may be some smoking and
White
a visible film may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.
Glass must be cleaned periodically to remove any film (which is
a normal by-product of combustion) which may be visible. Film
can easily be removed by removing the door, as shown on page
12. Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.
Silicone seals on inner door during initial firing will "off gas", leaving
a visual deposit of a white substance on combustion chamber walls.
This can easily be removed using normal household products.
Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.
Logs may be cleaned periodically with a vacuum to remove soot or
other contaminates.
Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass
etching may cause premature glass failure.
H-Series BF Gas Fireplace

Maintenance

General
Cleaning
WARNING: