Installing Terminations with Built-In Frames
11
11
1.
Frame the termination opening to 11" x 11".
2.
Fasten the termination to the studs using a minimum of 4
screws.
Installing Terminations with MSR Frames
12
12
1. Frame the termination opening to 12" x 12".
2. Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MOSR Frames
MOSR
PTO-3F (5"/8")
1.
Frame the termination opening to 12" x 12".
2.
Fasten the MOSR frame to the interior side of the studs using a
minimum of 4 screws.
3.
Insert the termination into the MOSR frame as shown here, and
attach by screwing through the four pilot holes in the termination.
Part No. XG0180
Installation
PTO-3F (5"/8")
MSR
PTO-3F (5"/8")
12 12
12
Installing Heat Guards over Terminations
Ensure that the two long mounting brackets are facing the bottom
1.
of the termination. (See inset). This will provide more heat protection
at the top of the termination, where temperatures are highest.
2.
Attach to the faceplate of the termination using four sheet metal
screws.
Installing The Standoffs
To avoid elevated mantel temperatures, all L-Series DF gas
fireplaces are required to have the supplied standoffs installed.
The fireplace is supplied with two standoffs. Bend and install these
standoffs on top of the fireplace ensuring that the height of the standoff
maintains a 6" clearance.
Figure 6b. Installing the standoffs.
Installing the Nailing
Flange Extension
Once the fireplace is placed into the framed opening, the supplied
nailing extension must be placed along the top edge of the fireplace,
and nailed in place to the framing, as illustrated below.
Figure 6c. Installing the Nailing Flange Extension.

Installing The Remote Switch

The L-Series DF's gas valve, located behind the lower trim, may be
connected to a wall switch. The valve generates its own power on a
millivolt circuit. Use only low voltage wire, and DO NOT connect
any external power to it.
Note: The switch location must not exceed 30' from the fireplace.