Section 9: Start-up Sequence with Continuous Pilot
for Your safeTY - read Before liGhTinG:
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and must be installed for the protection
of children and other at-risk individuals.
A. This appliance has a pilot which must be lit by hand.
WarninG if the information in these instructions are not followed
When lighting the pilot, follow these instructions exactly.
exactly, a fire or explosion may result causing property damage,
B. BEFORE LIGHTING smell all around the appliance area for
personal injury or death.
gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WarninG / cauTion: hot while in operation. do not touch.
What To Do If You Smell Gas:
severe burns may result. Keep children, clothing, furniture,
Do not try to light any appliance.
gasoline and other liquids having flammable vapors away.
Do not touch any electrical switch; do not use any phone
in your building.
see installation and operating instructions accompanying this appliance.
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
A. This appliance has a pilot which is lit automatically. Do
If you cannot reach your gas supplier, call the Fire
not attempt to light the pilot by hand.
Department.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
What To Do If You Smell Gas:
Do not try to light the appliance.
Do not touch any electrical switch. Do not use any
1. STOP! Read the safety information above on this label.
phone in your building.
2. Locate the gas control behind the lower trim, or on the
Immediately call your gas supplier from a
rear left side (on Cast stoves).
neighbour's phone. Follow the gas suppliers
instructions.
3. Push in gas control knob and turn clockwise
"OFF."
4. Wait five (5) minutes to clear out any gas. Smell for gas,
including near the floor. If you smell gas, STOP! Follow "B"
in the safety information above on this label. If you don't
1. STOP! Read the safety information above on this label.
smell gas, go to the next step.
5. Locate pilot burner (See illustrations and follow steps
2. Turn the fireplace "OFF" using the wall switch or remote
below.
control.
3. Wait 5 minutes to clear out any gas. If you smell gas,
STOP! Follow "B" in the safety information above on
this label. If you don't smell gas, go to the next step.
4. Turn the fireplace "ON" using the wall switch or remote
control.
NOTE: This unit is equipped with an ignition system
that lights the pilot burner automatically. Do not
attempt to light the pilot by hand.
Robert Shaw Valve
This unit is equipped with advanced safety
NOTE: Knob cannot be turned
controls including pre and post purge timers.
from "PILOT" to "OFF" unless
The fireplace will not turn on until all of the
knob is pushed in slightly. Do
safety conditions are met. The fans in the
not force.
fireplace may operate for an extended period of
time even after the wall switch is turned off.
To Turn off Gas To appliance:
1. Turn the fireplace off using the wall switch or remote
control.
2. Turn off all electrical power to the appliance.
1. Turn fireplace off using wall switch or remote control.
2. Locate the gas control behind the lower trim, or on the
rear left side (on Cast stoves).
XG0150 - 140707.2
Operation
Operation
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
DANGER
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, don't try to repair it. Call a qualified service
Lighting Instructions:
technician. Force or attempt to repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system, and any gas control which has been
under water.
liGhTinG insTrucTions:
5. The wall switch LED and heat sensor LED will light up.
6. Once the predetermined airflow is established in the
firebox, the flue gas switch LED will light up after 30
seconds.
7. After approximately 1 minute the hot surface igniter will
start to glow. The pilot will light up, followed by the main
burner. The fireplace will then start up.
NOTE: If the igniter does not glow, even after 3 minutes
have passed, follow the instructions "To Turn Off
Gas To Appliance" and call your service
technician or Montigo dealer.
SIT 820 HI/LO Valve
Control box LED lights
3. Locate the gas shut off valve for the appliance and
turn off.
To Turn Off Gas To Appliance:
WARNING
If the information in these instructions is not followed exactly, a
fire or explosion may result causing property damage, personal
injury or death.
WARNING/ CAUTION: Hot while in operation. Do not touch. Severe burns
may result. Keep children, clothing, furniture, gasoline and other liquids
having flammable vapours away.
See installation and operating instructions accompanying this appliance.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it. Call a qualified service
technician. Force or attempt to repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system, and any gas control which has been
under water.
6. Turn knob on gas control counter clockwise
"PILOT."
7. Push in gas control knob completely and hold. Light with
Piezo Igniter button. Continue to hold the control knob in
to
for about (1) minute after the pilot is lit. Release the knob
and it will pop back up. Pilot should remain lit. If it goes
out repeat steps 3 through 7.
If knob does not pop up when
released, STOP! Immediately call
your service technician or gas
supplier.
If the pilot will not stay lit after
several tries, turn the gas control
knob to "OFF" and call your
service technician or gas supplier.
8. Push in gas control knob and turn counter clockwise
to "ON."
9. Turn on remote switch to ignite fire.
3. Push in gas control knob slightly and turn
clockwise to "Off". Do not force.
4. Turn incoming gas control valve to off
Divine Outdoor Gas Fireplace
to
Typical pilot shown, see
instruction manual for
pilot specific to your
model.
Page 19