Image 15-4
7. Reinstall the side cover of the projector, see "Installation of the side cover", page 183.
C
AUTION
15.3 Replacement of the dust filter on the top side
Necessary parts
New HEPA dust filter for the top side (R9854480).
How to replace the HEPA dust filter on the top side of the projector ?
1. Remove the side cover of the projector, see "Removal of the side cover", page 180.
2. Remove the filter (F) on the top side by pulling out the filter holder (H) as illustrated.
Image 15-5
3. Place a new HEPA dust filter in the filter holder.
4. Reinstall the filter holder containing the new HEPA filter.
5. Reinstall the side cover of the projector, see "Installation of the side cover", page 183.
C
AUTION
15.4 Pressure verification of the liquid cooling circuit
How to check the pressure of the liquid cooling circuit inside the projector ?
1. Remove the side cover of the projector, see "Removal of the side cover", page 180.
2. Check the pressure indicated on the internal manometer of the liquid cooling circuit.
R59770180 FLM HD20 11/07/2008
A
:
Never install a used HEPA filter. Always install a new HEPA filter.
: