Parallel Interface - Citizen CL-S700DT User Manual

Direct thermal barcode & label printer
Table of Contents

Advertisement

Parallel Interface

Specifications
Transmission mode
8-bit parallel data
Receive buffer size
16K bytes
Compatible mode
Transmission modes
It is an asynchronous forward direction of the byte
width (from host to printer) channel, and the interface
line of the data is operated in accordance with signal
line definitions of Centronics.
NIBBLE mode
Nibble mode is asynchronous reverse channel
communication with data transmission controlled by
the host computer. In reverse channel transmission, the
data is nibble transmitted in two parts using four status
lines (Fault, Select, PE, and Busy). And nibble mode can
be used along with compatible mode to send data in
two directions.
ECP mode
ECP mode permits bi-directional asynchronous data
transmission, and thanks to its interlock handshake, it
does not require the timing necessary with compatible
mode.
Signal level
IEEE1284 standard
Signal line and pin assignment table
Pin No.
Signal name
1
*STROBE
2-9
DATA1-8
10
*ACKNLG
11
BUSY
12
PERROR
13
SELECT
14
AUTOFD
15
NC
16
GND
17
FGND
18
P.L.H
19-30
GND
31
*INIT
32
*FAULT
33-35
NC
36
SELECTIN
55
I/O
Function
Input
Strobe signal to read in 8-bit data
Input
8-bit parallel signal
Output
8-bit data request signal
Output
Signal specifying printer busy
Output
Signal specifying media out
Signal specifying if the printer is on-line
Output
(printing enabled) or off-line (pausing)
Input
Invalid (ignored)
------
Not used
------
Signal ground
------
Frame ground
Peripheral logic high (pull up to +5V at
Output
1k Ω )
Ground for twisted pair return
------
Printer reset
Input
Signal specifying printer error
Output
Not used
------
Invalid (ignored)