Troubleshooting Tips; Mc Series; Www.intelix.com - Intelix 8002MCB-XLR User Manual

Mc series 8 x 2 mic/line mixers
Table of Contents

Advertisement

MC Series

4.0 Troubleshooting Tips

NO POWER
Check the connections between the mixer and the power supply and the external
AC power supply.
Check the wall outlet.
NO SOUND
Make sure the mic/line switch is in the proper position. (This is the most likely
cause.)
Make sure both the master and channel input controls are turned up.
Check that the source signal cable(s) is properly connected and undamaged.
Adjust trim/gain potentiometer(s) to increase gain.
If there is still no sound, try changing input source(s) to different channel(s).
Make sure that jumper J1 is in place.
DISTORTED SOUND
Turn down the master volume control. If distortion persists, input channel(s) is
likely cause.
Check position of all line/mic switches.
Check the position of DIP switch number 8 it should be in the up position unless
you have special reset requirements.
Determine the distorting input channel(s) by checking them one at a time.
Decrease gain of input channel(s) causing distortion. (By turning the gain/trim
control potentiometer on the rear panel.).
EXCESSIVE HISS or HUM
Hiss: Make sure the volume control knobs for all the unused channels are set at "0"
and in line position. Make sure the mic/line switch is in the correct position for both
the input and output.
Hum: Mics lines can easily cause hum. Make sure to locate them away from vibration
and magnetic field sources (motors, power supplies and lines, and data lines).
Check mic lines, especially the shield, for damage.
Another common source of hum is a ground loop, which can result from connecting
two or more powered devices together. Turn the master volume down. If the hum is
still present, the ground loop or other cause is not in the mixer, but in the connections
or devices after the mixer in the audio path.
If the hum is "in" the mixer, first check to see if the Ground Lift Jumper (J4) is
present. It should be removed, unless the mixer is in a nonmetal cabinet. Check for
unbalanced connections; use balanced connections, if possible. For all unbalanced
connections, try to disconnect the signal line ground to "lift" the ground.
20

www.intelix.com

Intelix LLC
2222 Pleasant View Road
Middleton, WI 53562
User Manual
User Manual
User Manual
User Manual
User Manual
Phone: 608-831-0880
Toll-Free: 1-866-4-MATMIX
Fax: 608-831-1833

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8002mcb-fp8002 mcb-phnx

Table of Contents