Installation - Graco 311365G Repair Manual

Portable airless spraying of architectural coatings and paints
Table of Contents

Advertisement

Installation

WARNING
If pump pin works loose, parts could break off
due to force of pumping action. Parts could
project through the air and result in serious
injury or property damage.
CAUTION
If the pump jam nut loosens during
operation, the threads of the drive housing
will be damaged.
1. Extend pump piston rod 1.5 in. Apply
grease to top of pump rod at (A) or inside
connecting rod.
A
ti7171a
311365G
2. Install pump pin (44). Verify retaining spring
3. Push pump up until pump threads engage.
4. Screw in pump until threads are flush with
5. Install washers, o-rings and suction tube
6. Screw jam nut (56) up onto pump until nut
7. Install pump rod shield (108) with screw
8. Fill packing nut with Graco TSL until fluid
1.5 in.
Displacement Pump Replacement for 695/795
(43) is in groove of connecting rod (85).
drive housing opening. Align pump outlet to
back.
(76) and hose (94).
stops. Tighten jam nut by hand, then tap
1/8 to 1/4 turn with a 20 oz (maximum)
hammer to approximately 75± 5 ft-lb (102
N•m).
(31).
flows onto top of seal.
ti716 a
35