Displacement Pump Replacement 1095/1595/Mark V; Removal - Graco 311365G Repair Manual

Portable airless spraying of architectural coatings and paints
Table of Contents

Advertisement

Displacement Pump Replacement 1095/1595/Mark V

Removal

1. Flush pump.
2. Stop pump with piston rod in its lowest
position.
Read Skin Injection Hazard; page 5.
3. Do Pressure Relief, page 9.
4. Separate drain hose from sprayer.
ti7326a
5. Disconnect paint hose from pump.
ti6300a
6. Raise latch lock. Push latch open.
ti636 a
36
Displacement Pump Replacement 1095/1595/Mark V
7. Ratchet open pump door.
a. Ratchet pump door forward.
b. Twist latch u-bolt out of pump door
recess.
c. Place u-bolt on pump door outer edge.
d. If pump door is stuck, do steps e, f, and
8, otherwise go to step 9.
e. Twist latch u-bolt back from pump door
outer edge.
ti6374a
f. Place u-bolt on pump door protrusion.
ti637 a
ti6370a
ti6373a
311365G

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents