Graco 311365G Repair Manual page 29

Portable airless spraying of architectural coatings and paints
Table of Contents

Advertisement

Installation
1. Install o-ring (20) and transducer (86) in
filter base (67). Torque to 35-45 ft-lb (47-61
N•m). Install grommet onto transducer (86)
and transducer into control box.
40
67
86
20
ti13496a
2. Connect transducer connector (E) to motor
control board (95).
E
ti12999a
311365G
3. Install control box (61) and control panel
ti7447a
4. Connect potentiometer connector (C) to
95
5. Install cover (96) with four screws (38).
(68) with four screws (39).
39
ti13494a
61
motor control board.
C
96
38
Pressure Control Board
ti74 8a
68
ti12997a
ti13493a
29