Changing Frequency Setting; Operation Cfl Mode; Automatic Demonstration Program; Operation Safe-Exit - Casablanca Antion C39G199L Owner's Manual

Antion
Table of Contents

Advertisement

1
2

OPERATION CFL MODE

0
4
3
1
2
Your fan has the ability to disable the dimming feature to allow the use of
CFL bulbs.
0
4
3
To activate CFL mode:
1._ Turn the fan off by pressing the
power button.
2._ Allow the fan to remain off for at least 5 seconds.
3._ Press the power button again to restore power to the fan.
4._ Immediately press and hold the "1" and "3" buttons for at least 5 seconds. The fans lights will go to
1
2
100% brightness and the dimming function will be disabled.
0
4
3
To cancel CFL mode:
5._ Turn the fan off by pressing the
power button.
6._ Allow the fan to remain off for at least 5 seconds.
7._ Press the power button again to restore power to the fan.
8._ Immediately press and hold the "2" and "4" buttons for at least 5 seconds. The fans lights will dim to
50% brightness and the dimming function will be enabled. Press and hold the light buttons until the
desired dimmer setting is reached.

CHANGING FREQUENCY SETTING

NOTE: All fans leave the factory set to
"111111"
You will only have to change the dip switch settings in the remote if you
are using more than one fan in the same area and want to control them
separately.
NOTE: DO NOT set dip switch setting in the
remote to '0000', this may cause frequency
interference from other Casablanca Products.
1._ Turn power OFF at the circuit breaker or fuse box and at the toggle
switch, for the fan you want to change.
2._ Remove the screws and switch plate from the existing switch box.
3._ Remove the screws holding the switch in the switch box.
4._ Pull the existing W-74 switch from the switch box to expose the dip
switches located on the side of the control as shown in Figure #1.
5._ Change the dip switch settings, assuring that they are different from
the previously installed Direct-Touch fan.
6._ Mount the W-74 Wall Control unit back into the wall electrical box.
7._ At the circuit breaker or fuse box and at the toggle switch, turn the
power off for the fan whose frequency you are changing.
8._ Within 20 seconds of restoring power to the ceiling fan and the W-74
Wall Control press and hold both the "1" and
as shown in Figure #2. For 3 seconds, you will hear one tone from
the Piezo Buzzer indicating the command has been accepted. The Fan
and Lights will be off.
22
Caution: CFL bulbs will not
function properly when
dimmed, which may result
in flickering or reduced bulb
life.
DIP
SWITCHES
DIP SWITCHES
SET TO '111111'
(Factory Setting)
(Figure 1)
DIP SWITCHES
SET TO '000000'
1
2
0
4
3
reverse buttons
(Figure 2)

AUTOMATIC DEMONSTRATION PROGRAM

Programmed into every Direct-Touch fan is an Automatic Demonstration
1
2
Program. It can be used to fully demonstrate and test the operation of the
fan.
0
4
3
1
2
To_enter_the_demonstration_program:
0
1._ Turn the
power button off for at least 5 seconds. This will clear
4
3
the fan memory ready for programming.
2._ Turn the
power button on.
3._ Immediately hold the "0" button for at least 5 seconds.
A multi-tone signal will verify the start of the test program. The fan and
1
2
lights will go through a series of changing fan speeds, reversing the fan
0
operation mode, turning off/on, and dimming the lights.
4
3
The complete cycle lasts slightly over one minute. It will continue to
repeat until the
is turned off for more than five seconds, cancelling
the program.
OPERATION SAFE-EXIT®
1
2
The Safe-Exit Program gives you about thirty seconds of light when you turn the
0
lights off, enabling you to exit your home before the lights go out. To enter the Safe-
4
3
Exit Program:
1._ Press the
power button off for at least five seconds.
2._ Turn the Power on. Immediately press and hold the "4" button for 5 seconds.
When a light button is pressed, an audio tone and series of lights blinking will indicate the program
1
2
is active. When CFL mode is disabled, the Lights will stay on at 50% brightness for 20 seconds then
0
decrease in intensity for 30 seconds then turn off.
4
3
3._ With CFL mode active, the lights will turn off after 30 seconds.
4._ To cancel the Safe-Exit Program, press the
LIGHT-MINDER® PROGRAM
The Light-Minder Program automatically turns OFF the fan mounted lights after two
hours. To enter the Light-Minder Program:
1
2
0
1._ To operate the lights for Light Minder Program – Turn the
4
3
for at least 5 seconds.
2._ Turn the
on. Immediately press and hold the "1" button for 5 seconds. A
series of tones will be heard through the piezo-buzzer indicating the command
has been accepted. Once the lights turn on, they will automatically turn off after
2 hours.
3._ Light operation still remains normal, if you leave the room and turn OFF the
1
lights, the lights will blink to indicate the Light Minder command has been
0
accepted. The lights will stay on for 2 hours and then begin to dim. After thirty seconds have elapsed,
4
the lights will turn completely off. In CFL Mode, the lights will not dim, but shut off after 2 hours.
4._ To cancel the Light Minder Program, press the
Direct - Touch
Note: With CFL mode active,
the lights will not dim.
Safe-Exit
power button and leave off for five seconds.
1
2
0
4
3
power button off
Light-Minder
2
3
power button and leave off for five seconds.
23
1
2
0
4
3

Advertisement

Table of Contents
loading

Table of Contents