W-74 WALL CONTROL PREPARATION

4
3
WARNING!
To avoid possible electrical shock, make
certain that electricity is turned off at the
circuit breaker or fuse box before attempting
any installation or repair procedure
CAUTION! NOT turning the power OFF at the
circuit breaker or fuse box may cause damage
to the electronics within the wall control and or
the PC board on the fan.
18
Circuit Breaker
Fuse Box
(Trip breaker for the
(Remove fuse for the
circuit you will be
circuit you will be
working on)
working on)
W-74 CONTROL INSTALLATION

INSTALLING THE W-74 WALL CONTROL

NOTE: W-74 Wall Control should only be installed on Casablanca's Direct-Touch
The wall control installs in the same manner as an ordinary light switch, using an existing wall box and
wiring. This controller is designed to signal the fan microcomputer as well as perform normal switching
operations. For this reason the following precautions must be observed:
1. Use only the Casablanca W-74 wall control.
2. Do not use any additional control with your
Direct-Touch
fan (for example, dimmer, or fan
TM
speed control).

SINGLE W-74 INSTALLATION

CAUTION!
Ensure power is turned OFF at the breaker or fuse panel before starting installation.
1._ If you have multiple Direct-Touch
TM
fans, refer to the
section "changing frequency setting" on page 20.
2._ Remove the screws and switch plate from the existing
switch box.
3._ Remove the screws holding the switch in the switch
box.
4._ Pull the existing switch from the switch box to expose
the wire connections.
5._ Remove the two wires from the switch.
6._ Connect the BLACK wire from the POWER SOURCE
that you just removed from the switch to the BLACK/
WHITE STRIP wire on the W-74 wall control. Secure
this connection with a wire nut.
7._ Connect the second BLACK wire that you just removed
from the switch to the second BLACK wire on the
located on the back of the W-74 wall control. Secure
this connection with a wire nut.
NOTE: The RED wire is not used in this
application. DO NOT remove the crimped
cap from the wire.
8._ Connect the green ground wire coming
from the back of the W-74 control to the
ground wire in the switch box. Secure
the splice with a wire nut.
9._ Check your work by using the wiring
diagrams as shown in Figures # 1 and #2.
10._ Install the W-74 in the wall box with the
two long screws provided.
11._ Install the wall plate with the two white
screws.
Direct - Touch
TM
Fans.
3. Do not use more than one fan per wall control.
4. No other light fixtures or electrical appliances
may be connected on the circuit controlled by the
W-74 wall control.
Red
White
Blue
Black/White
W-74
Figure_1
2 BLACK
WIRES
W-74
Wall Control
RED WIRE
NOT USED
BLACK AND WHITE
STRIPED WIRE