Wiring - Casablanca Panama EnErgy Star C66U11B Owner's Manual

Panama energy star
Table of Contents

Advertisement

Trim Ring
Canopy
Step 1. Locate the White wire marked "NEUTRAL IN"
and connect it to the White Neutral Wire from your
ceiling using one of the supplied orange wire caps.
Step 2. Connect the Black wire marked "POWER IN
and the Black Power Wire from your ceiling with an
orange wire cap.
Step 3. Tuck the White and Black connected wires
back into the ceiling box through the hole in the
center of the Hanger Bracket while you slide the
Receiver into the open end of the Hanger Bracket as
shown.
NOTE: Ensure you do not tuck the bare ground
wire from the ceiling back into the box. This will be
connected later.
Step 4. Connect the (Light) Blue wire marked LIGHT
OUT from the Receiver to the Blue Wire coming from
the fan with a blue wire cap.
P
E
®
anama
WIRING HARDWARE
Receiver

WIRING

s
nErgy
tar
Blue Wire Caps (4)
Power From
Ceiling
White
Neutral From
Ceiling
Bare Ground
Wire
Orange Wire Caps (3)
Line Power
(IN) RED TAG
Line Neutral
(IN) RED TAG
Tuck Wires
in Box
Blue -Downlight
Power