Chapter 1 Overview
The configuration of the system is listed in Table 1-1.
Component
Rectifier
Monitoring module
AC power distribution
DC power distribution
Battery routes
Others
The monitoring module is available in three different models. Their configurations are listed in Table 1-2.
Models
M522B
M523B
M221B

1.3 Features

 The rectifier uses the active Power Factor Compensation (PFC) technology, raising the power factor to 0.99.
 The system has wide AC input voltage range: 90Vac ~ 290Vac.
 The rectifier uses soft switching technology, raising the efficiency to 91%.
 The rectifier has ultra-low radiation. With advanced EMC design, the rectifier meets international standards such
as CE, NEBS and YD/T983. Both the conducted and radiated interference reach Class B.
 The rectifier safety design complies with UL, CE and NEBS standards.
 The rectifier is of high power density.
 The rectifier is hot pluggable. It takes less than 1min to replace a rectifier.
 The rectifier has two over-voltage protection methods: hardware protection and software protection. The latter
one also has two optional modes: lock-out at the first over-voltage and lock-out at the second over-voltage.
 The monitoring module has perfect battery management. The management functions include battery low voltage
disconnection (BLVD), temperature compensation, auto voltage regulation, stepless current limiting, battery
capacity calculation, on-line battery test, and so on.
 The monitoring module can save up to 200 pieces of historical alarm records, and 10 sets of battery test data
records.
 The monitoring module is of network design. With an RS232 port, Ethernet, dry contacts and other
communication ports provided, flexible networking is enabled to achieve remote monitoring and unattendance.
 The system has complete fault protection and fault alarm functions.
Table 1-1 Configuration of the system
NetSure 211 C45-S1
Model: R48-1000
Standard configuration: 4 pieces
Model: M522B, M523B or M221B
Standard configuration: 1 piece
AC input mode:
L + N + PE/220V, no AC input MCB
8 load MCBs:
4 × 20A/1P, 4 × 25A/1P
2 battery MCBs:
2 × 63A/1P
Two digital input ports, two dry contact output
ports, two temperature sensor ports
Table 1-2 Configuration of the monitoring module
2DI + 2DO, LCD display, network port, RS232 port
2DI + 2DO, LCD display, RS232 port
2DI + 2DO, no LCD display, three LED indicators indicating operation status of the system, RS232 port
NetSure 211 C45 Embedded Power Supply System User Manual
Configuration
NetSure 211 C45-S2
AC input mode:
L + N + PE/220V, 1 × 40A/2P MCB
4 load MCBs:
2 × 20A/1P, 2 × 10A/1P
1 battery MCB:
1 × 63A/1P
One digital input port, two dry contact output
ports, two temperature sensor ports
Configuration