Emerson netsure 9500 Operation Manual

Emerson netsure 9500 Operation Manual

120kw 400v dc power system

Advertisement

Quick Links

NetSure
9500 120kW 400V DC Power System
Operation Manual, UM584001200 (Issue AA, April 14, 2014)
Specification Number: 584001200
Model Number: 9500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the netsure 9500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson netsure 9500

  • Page 1 ™ NetSure 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Specification Number: 584001200 Model Number: 9500...
  • Page 2 NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) This page is intentionally blank. Spec. No: 584001200 Code: UM584001200 Model No: 9500 Issue AA, April 14, 2014...
  • Page 3: Table Of Contents

    NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Table of Contents Admonishments Used in this Document ........................ ii Important Safety Instructions ..........................iii General Safety ................................iii Voltages ..................................iii Battery (if equipped) ..............................iii Personal Protective Equipment (PPE) .........................
  • Page 4: Admonishments Used In This Document

    NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Admonishments Used in this Document DANGER! Warns of a hazard the reader will be exposed to that will likely result in death or serious injury if not avoided.
  • Page 5: Important Safety Instructions

    NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Important Safety Instructions General Safety DC Output and Battery Voltages DANGER! DANGER! This system produces DC Power and may have YOU MUST FOLLOW APPROVED SAFETY PROCEDURES. a battery source connected to it.
  • Page 6: Personal Protective Equipment (Ppe)

    NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) FOR THESE REASONS, IT IS OF CRITICAL IMPORTANCE WARNING! A battery can present a risk of electrical shock and high short circuit current. Servicing of THAT YOU READ THESE INSTRUCTIONS AND FOLLOW Warning batteries should be performed or supervised only by...
  • Page 7: Hazardous Voltage

    NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Dual Hazardous Input Power Sources Observe all safety precautions in this manual and in the battery instruction manual before as well as during performance of all maintenance procedures. Observe WARNING! The system may be powered from dual all battery safety precautions before working on or near hazardous input power sources simultaneously:...
  • Page 8: Static Warning

    Before touching any equipment containing static sensitive components, discharge all static electricity from yourself by wearing a wrist strap grounded through a one megohm resistor. Some wrist straps, such as Emerson Network Power Part Number 631810600, have a built-in one megohm resistor; no external resistor is necessary. Read and follow wrist strap manufacturer’s instructions outlining use of a specific wrist strap.
  • Page 9: Customer Documentation Package

    NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Customer Documentation Package System Description This document (UM584001200) provides Operation Instructions for 400V DC Output @ up to 120kW Power System NetSure™ 9500 120kW 400V DC Power System Model 9500, Spec. The NetSure™...
  • Page 10: Distribution Module/Bay (List 07)

    • Emerson Provided Battery Cabinet Local Controls and Indicators Emerson offers a choice of battery models factory Refer to the controller and rectifier instructions for descriptions of installed and connected in a cabinet (List 90, 91, 92, 93). the local controls and indicators located on these units.
  • Page 11: Distribution Panel Lockout/Tagout (Loto)

    (If off when system is in Missing Ground: The HRMG grounding lead that exits the operation, contact Emerson Technical Support.) (The converter power and control sub-rack is not connected to ground. power supply provides 48V DC for controls.) •...
  • Page 12 NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Figure 1. Power and Control Section Controls and Indicators Output Control Voltage Voltage Ground/Insulation Present Present Fault Alarm Indicator Indicator Indicator Output Control Ground/Insulation Voltage Voltage Fault...
  • Page 13: Adding A Circuit Breaker To A List 21Ha Distribution Panel

    Operation Manual, UM584001200 (Issue AA, April 14, 2014) Adding a Circuit Breaker to a List 21HA Distribution Maintenance Panel Contact Emerson Network Power for all of your maintenance Danger! Hazardous DC voltage (400V DC) is present. needs. The distribution panel MUST be completely isolated...
  • Page 14: Troubleshooting And Repair

    Lockout/Tagout (LOTO) system is an ACU+ configuration drawing (C-drawing) and the ACU+ configuration files loaded into the ACU+ as The “Battery Disconnect Circuit Breaker” on an Emerson Battery Cabinet contains a bracket which allows the circuit breaker to be shipped.
  • Page 15: Replacement Information

    NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Replacement Procedures Press ENT to select the operation. Press ENT again to confirm. Danger! Adhere to the “Important Safety Instructions” Return to the Main screen by repeatedly pressing ESC presented at the front of this document.
  • Page 16 NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Replace the distribution panel’s top or bottom front distribution leads are terminated in a 2-hole lug and the DC input bus leads are terminated in a single-hole lug. cover.
  • Page 17 NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Figure 2. Adding or Replacing a DC Distribution Circuit Breaker in a List 21HA Distribution Panel to +200V DC Load to +200V DC Load Distribution Terminal Distribution Terminal to +200V DC...
  • Page 18 NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Disconnect the surge protector wiring from the surge Replacing an AC Input Surge Protector protector wiring terminal block. Danger! Hazardous AC voltage (380V/400V/480V AC) is Unplug the surge protector plug-in connector from the present behind the access covers being removed in this Danger...
  • Page 19 NetSure ™ 9500 120kW 400V DC Power System Operation Manual, UM584001200 (Issue AA, April 14, 2014) Figure 3. AC Input Surge Protector Replacement Power and Control Section AC Surge Protector Rear AC Surge Protector Plug-In Connector AC Surge Protector Terminal Block AC surge protector ground AC Surge Protector lead is routed into main AC...
  • Page 20: Netperform™ Optimization Services (North America)

    NetPerform™ Optimization Services (North America) At Emerson Network Power, we understand the importance of reliable equipment – it’s critical to both your business and your bottom line. That is why we offer a wide array of services to meet all of your network infrastructure needs.
  • Page 21: Netperform™ Optimization Services (Emea)

    NetPerform™ Optimization Services (EMEA) At Emerson Network Power, we understand the importance of reliable equipment – it’s critical to both your business and your bottom line. That is why we offer a wide array of services to meet all of your network infrastructure needs.
  • Page 22 Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Powe r, Energy Systems, North America, Inc. Any copying, use or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

Table of Contents