Selecting a Site

TigerStack II 10/100 hubs can be mounted in a standard 19-inch
equipment rack or on a flat surface. Be sure to follow the
guidelines below when choosing a location.
The site should:
K
• be able to maintain its temperature within 0° to 50° C and
its humidity within 0% to 90%, non-condensing
• provide adequate space (approximately two inches) on all
sides for proper air flow
• be accessible for installing, cabling and maintaining the
devices
• allow the status LEDs to be clearly visible
Make sure twisted-pair cable is always routed away from power
K
lines, fluorescent lighting fixtures and other sources of electrical
interference, such as radios, transmitters, etc.
Make sure that a separate grounded power outlet that provides
K
100 to 240 VAC, 50 to 60 Hz, is within 8 feet (2.44 m) of each
device and is powered from an independent circuit breaker. As
with any equipment, using a filter or surge suppressor is
recommended.